2-1-4.
Indoor Unit
Outdoor Unit
Voltage Rating
Total Capacity
Sensible Capacity
Latent Capacity
Air Circulation (Hi/Me/Lo)
Moisture Removal (High)
Available Voltage Range
Running Amperes
Power Input
Power Factor
EER
SEER
Compressor Locked Rotor Amperes
Fuse or Circuit Breaker Capacity
Controls / Temperature Control
Control Unit
Timer
Fan Speeds
Airflow Direction (Indoor)
Air Filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant Control
Operation Sound
Refrigerant Tubing Connections
Max. allowable tubing length at shipment
Refrigerant
Tube Diameter
Wired Remote Controller (Option)
CS-KS18NB4UW & CZ-18BT1U
CU-KS18NKUA
ft
3
/min (m
BTU/h/W
BTU/Wh
Indoor / Outdoor
Horizontal
Indoor : Hi/Me/Lo
Outdoor : Hi
Narrow tube
inch (mm)
Wide tube
inch (mm)
BTU/h
kW
BTU/h
BTU/h
3
/h)
341 (579) / 294 (500) / 253 (430)
Pints/h
V
A
W
%
A
A
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps / Auto (Hi and multi steps)
Vertical
Ibs (g)
dB-A
dB-A
ft (m)
13
230V Single-Phase 60Hz
Cooling
17,500
( 4,000 to 17,500 )
5.15
( 1.2 to 5.15 )
10,600
6,900
4.89
187 to 253
8.3
( 1.2 to 8.3 )
1,860
( 250 to 1,860 )
97
9.41
16
17.5
15
-
Auto
Washable, Anti-Mold
DC Twin Rotary (Inverter)
R410A / 2.87 (1,300)
Electric Expansion Valve
44 / 40 / 36
51
Flare Type
25 (7.5)
1/4 (6.35)
1/2 (12.7)
CZ-RD515U
< 230V >