Operating Instructions Split System Air Conditioner Model No. Indoor Units Outdoor Units CS-KS18NKU CU-KS18NKU CS-KS24NKU CU-KS18NKUA CU-KS24NKU CU-KS24NKUA This air conditioner uses the refrigerant R410A. Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
FEATURES This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner. • Microprocessor Controlled Operation • Air Sweep Control The interior compartment of the remote controller This function moves a flap up and down in the air outlet, contains several features to facilitate automatic operation, directing air in a sweeping motion around the room and...
INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
Page 4
• To prevent possible hazards from insulation failure, the unit must be grounded. • Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning. • In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.
NAMES OF PARTS Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose Refrigerant Tubes OUTDOOR UNIT Air Outlet This illustration is based on the external view of a standard model. NOTE Consequently, the shape may differ from that of the air conditioner which you have selected.
UNIT DISPLAY AND OPERATION BUTTON INDOOR UNIT IMPORTANT OPERATION lamp TIMER lamp Avoid using radio equipment QUIET lamp QUIET such as mobile phone near (within 4 ft (1.2m).) the remote control receiver. Some radio OPERATION button equipment may cause malfunction of the unit. If the trouble happens, disconnect power and restart REMOTE CONTROL receiver...
Page 7
REMOTE CONTROLLER (DISPLAY) Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when setting timer Displayed when the time display is set to 12-hour time. Symbols (1) Operation mode (4) Timer 24-hour clock with ON/OFF MILD DRY ......
REMOTE CONTROLLER Sensor Transmitter (Cover closed) Display ON/OFF operation button QUIET button 1 HR. TIMER button Temperature setting buttons (TEMP.) MODE selector button FAN SPEED selector button NIGHT SETBACK button FLAP button HIGH POWER button ON TIME Advance button OFF TIME Advance button setting setting...
Page 9
REMOTE CONTROLLER (CONTINUED) Temperature setting buttons Press the button to increase the set temperature. (TEMP.) Press the button to reduce the set temperature. The temperature setting changes by 1 °C or 2 °F each time one of the TEMP. buttons is pressed. MODE selector button Use this button to select DRY, COOL or FAN mode.
REMOTE CONTROLLER (CONTINUED) Temperature Display Selector button This switches the temperature display between °C and °F. Time Display Selector button This switches the time display between 24-hour time and 12-hour time. ACL button (ALL CLEAR) Puts the remote controller into pre-operation status. Always press this button after replacing the batteries.
Page 11
USING THE REMOTE CONTROLLER (CONTINUED) How to Use the Remote When using the remote controller, always point the unit’s transmitter head directly Controller at the air conditioner’s receiver. Air Conditioner (Indoor unit) Receiver Remote Controller (Transmitter head) Remote Controller Installation The remote controller may be operated either from a non-fixed position or from a Position wall-mounted position.
OPERATION WITH THE REMOTE CONTROLLER 1. Operation STEP 2 STEP 3 STEP 1 STEP 4 STEP 5 NOTE Check that the circuit breaker on the power panel is turned on. Press the setting buttons as described below and change the settings as desired. STEP 1 Press the MODE selector button and select the desired mode.
OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) • Choose the best position in the room for the remote controller, which also acts NOTE as the sensor for room comfort and transmits the operating instructions. Once you’ve found this best position, always keep the remote controller there. •...
OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 4. Night Setback Mode Night Setback Mode is used for saving energy. Press the NIGHT SETBACK button while unit is operating. (except FAN mode) mark appears in the display. To release the night setback function, press the NIGHT SETBACK button again. NOTE Pressing the MODE selector button cancels Night Setback mode.
OPERATION WITH THE REMOTE CONTROLLER (CONTINUED) 5. QUIET Mode QUIET Mode is used to reduce the fan sound of the indoor unit. Press the QUIET button. mark appears in the display. To cancel, press QUIET button again. • In QUIET Mode, the fan rotates at a slower speed than the fan speed setting. •...
SPECIAL REMARKS ‘‘DRY’’ ( ) Operation How it works? • Once the room temperature reaches the level that was set, the unit’s operation frequency is changed automatically. • During DRY operation, the fan speed automatically runs at lower speed for providing a comfortable breeze.
SETTING THE TIMER In the descriptions below, the following settings are used for the temperature and NOTE time indicator selector button on the bottom front section of the remote controller. • Temperature: °F • Time: AM, PM 1. How to set the present (Example) To set to 10:30 pm.
Page 18
SETTING THE TIMER (CONTINUED) 3. How to set the ON time (Example) To start operation at 7:10 am. Operation Indication 1. Press the ON TIME setting The timer indication is displayed, button once. and the present ON time is shown. 2.
USING THE 1-HOUR OFF TIMER 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. indicator in the display indicates that this function is operating. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR.
ADJUSTING THE AIRFLOW DIRECTION 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. When the humidity is high, the vertical vanes should be in the front CAUTION position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down.
OPERATION WITHOUT THE REMOTE CONTROLLER INDOOR UNIT If you have lost the remote controller or it has trouble, follow the steps below. When the air conditioner is not running Each time the OPERATION button is pressed, the operation mode changes cyclically.
Page 22
CARE AND CLEANING (CONTINUED) Filter The filter behind the air intake grille should be checked and cleaned at least once every two weeks. How to remove the filter 1. Grasp both ends of the air Air intake grille intake grille, and remove it by opening towards the front and pulling towards you.
CARE AND CLEANING (CONTINUED) Cleaning the main unit and • Wipe clean using a soft, dry cloth. Remote Controller • To remove stubborn dirt, moisten a cloth in warm water no hotter than 104 °F, wring thoroughly, and then wipe. •...
TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center. Trouble Possible Cause Remedy Air conditioner does not run at all. 1.
Need help?
Do you have a question about the CS-KS18NKU and is the answer not in the manual?
Questions and answers