 IGD-PGV output
Error code
Meaning
A0h
IGD-PGV voltage is over 1.80V.
A1h
IGD-PGV voltage is under 0.00V when the computer is powered on.
A2h
IGD-PGV voltage is under 0.00V when the computer is booting up.
 VCCSA-P0V output
Error code
Meaning
C0h
VCCSA-P0V voltage is over 1.08V.
C1h
VCCSA-P0V voltage is under 0.64V when the computer is powered on.
C2h
VCCSA-P0V voltage is under 0.64V when the computer is booting up.
 PTV output
Error code
Meaning
PTV voltage is over 1.26V.
D0h
PTV voltage is under 0.89V when the computer is powered on.
D1h
PTV voltage is under 0.89V when the computer is booting up.
D2h
 Miscellaneous
Error code
Meaning
F0h
The sub clock does not oscillate.
Check 2
In the case of error code 10h or 12h:
 Make sure the AC adapter and AC power cord are firmly plugged into the DC
IN 19 V socket and wall outlet. If the cables are connected firmly, go to the
following step.
 Connect a new AC adapter and AC power cord. If the problem still occurs, go
to Procedure 5.
Check 3
In the case of error code 21h:
PORTEGE Z830 Satellite Z830 Series Maintenance Manual (960-883) [CONFIDENTIAL]