Make Gas Connection - Jenn-Air 30" (76.2 CM) Installation Instructions Manual

30" (76.2 cm) slide-in dual fuel downdraft ranges
Table of Contents

Advertisement

Available languages

Available languages

2. Use
" nut driver to connect the neutral (white) wire and
copper ground strap provided to the center terminal block
post with one of the 10-32 hex nuts. The opposite end of the
copper ground strap should be secured to the oven back with
the green ground-link screw.
A
B
C
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
3. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
5. Replace terminal block access cover.

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Open access panel by grasping sides and pulling upward,
lifting out.
18
E
D
D. Neutral (white) wire
E. Line 2 (red)
2. Locate gas pressure regulator behind access panel.
A
A. Gas pressure regulator
3. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
4. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
5. Use a
" combination wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
B C
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male
pipe thread)
D. Flexible connector
6. Gas supply pipe must not be more than 10" (25.4 cm) above
the floor.
A. Flexible connector
B. Manual shutoff valve
C. 10" (25.4 cm) max. straight pipe
D
E
H
G
F
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jds9860cdsJds9865bdpJds9860cdsJds9865bdp

Table of Contents