Raid 1 (Adm) And Raid 10 (Adm) - HP ProLiant DL280 Reference Manual

Configuring arrays on hp smart array controllers reference guide
Hide thumbs Also See for ProLiant DL280:
Table of Contents

Advertisement

Advantages:
This method has the second highest read performance of any fault-tolerant configuration.
No data is lost when a drive fails, as long as no failed drive is mirrored to another failed drive.
Up to half of the physical drives in the array can fail.
Disadvantages:
This method is expensive, because many drives are needed for fault tolerance.
Only half of the total drive capacity is usable for data storage.

RAID 1 (ADM) and RAID 10 (ADM)

In RAID 1 (ADM) and RAID 10 (ADM) configurations, data is duplicated to two additional drives.
When the array contains only three physical drives, the fault-tolerance method is known as RAID 1 (ADM).
Drive arrays and fault-tolerance methods 107