Step 5. FIELd WIRING

CAUTION
The ground supply lead must be
connected to the wire attached to the
green ground screw located on the
outlet box (see wiring diagrams).
Failure to do so will result in a
potential safety hazard. The appli-
ance must be electrically grounded
in accordance with local codes or,
in the absence of local codes, the
National Electrical Code, ANSI/
NFPA 70-latest edition (in Canada,
the current CSA C22-1 Canadian
Electrical Code).
CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. des erreurs
de cáblage peuvent entraîner un fonc-
tionnement inadéquat et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
APPLIANCE- MOUNTED
ON/OFF SWITCH
(OPTIONAL)
TP-TH
TP
TH
GAS VALVE
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
FAN
(OPTIONAL)
JUNCTION BOX
Figure 47
PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45) • INSTALLATION INSTRUCTIONS
®
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-100 and FBK-200 Kits
1. If any of the original wire as supplied must be replaced,
1.
it must be replaced with Type AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
**ON/OFF Switch (Integral
with Gas Valve)
Gas Valve
BK
R
BL
OPT
BLOWER
W
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
OR OPTIONAL REMOTE RECEIVER
*Blower speed control switch is provided in FBK200 blower kit.
Factory Wired
Figure 48
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
1. If any of the original wire as supplied must be replaced,
1.
it must be replaced with Type AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
*ON/OFF Switch (Integral
with Gas Valve)
Gas Valve
BK
R
BL
OPT
BLOWER
WH
BK
R
W
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT
GR
Factory Wired
Schematic Representation Only
Figure 49
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
**Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
PILOT
ASSEMBLY
Green
White
G
o r
n u
- d
G
e r
n e
N
e
t u
a r
- l
W
h
e t i
120 VAC - Black
Black
Junction Box
Tab Intact
Tab
Broken
Red
Optional
Green
Accessory
Neutral
Hot
Ground
Side of
Switch
Side of
Screw
Receptacle
Receptacle
W
Transf.
B
120 V.
G
24 V
BL
R
BK
OR OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
Field Wired
Schematic Representation Only
FBK-250 Kits
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
PILOT
G
o r
n u
- d
G
e r
ASSEMBLY
N
u e
a r t
- l
W
h
120 VAC - Black
Optional
FBK-250
Module
Green
White
Black
Junction Box
Tab Intact
Tab
Broken
Red
Optional
Green
Accessory
Neutral
Hot
Ground
Switch
Side of
Side of
Screw
Receptacle
Receptacle
W
B
Transf.
120 V.
G
24 V
BL
R
BK
OR OPTIONAL REMOTE RECEIVER
Field Wired
Refer to Section A for millivolt appliances and
Section B for electronic appliances. The gas
valve is set in place and pre-wired at the factory
on both models.
A. Millivolt Wiring
(see Figure 47)
Millivolt units are not provided with any
factory-installed controls; therefore, one of the
optional control switches is required to operate
the unit (ON/OFF Wall Switch, Unit-Mountable
ON/OFF Switch*, Thermostat, Remote Control).
See the fireplace Care and Operation Instruc-
tions for details.
[*If using a Unit-Mountable ON/OFF Rocker Switch
with an optional Style View Door, mount the Rocker
Switch on the door instead of the unit.]
1. If installing an ON/OFF wall switch or ther-
mostat, mount it in a convenient location on
a wall near the fireplace.
2. Wire the control switch within the millivolt
control circuit using the 15 feet of 2 con-
ductor wire supplied with the unit.
Note: The supplied 15 feet of 2 conductor
wire has one end of each conductor con-
nected to the gas valve circuit and the other
end of each conductor placed loose inside
the bottom compartment.
CAUTION
In millivolt systems, do NOT connect
a Wall Switch to a 120V power supply.
B. Electronic Wiring
The electronic gas valve has an integrated ON/
OFF burner control switch. One of the follow-
ing optional controls also may be used: ON/
OFF Wall Switch, Thermostat, Remote Control
n e
e t i
(see fireplace Care and Operation Instructions
for details.).
Note: Electronic models must be connected to
the main power supply.
1. Route a 3-wire 120Vac 60Hz 1ph power
supply to the appliance junction box.
2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's
securing screws (see Figure 13, Page 11).
3. Remove the cover plate knockout; then feed
the power supply wire through the knockout
opening and into the unit junction box.
4. See Figures 48 & 49. Connect the black
power supply wire to the lower outlet's red
pigtail lead.
Connect the white power supply wire to the
outlet's common terminal.
5. Connect the ground supply wire to the
pigtail lead attached to the outlet's green
ground screw.
(see Figures 48 & 49)