Daily Inspection - Security Labs SL 700 User Manual

Time lapse video cassette recorder
Table of Contents

Advertisement

SW OUTPUT Terminal
While recording, a pulse signal(DC 5V) is output at the
SW OUT terminal after each recording period. This
terminal is usually connected to the switch input of
devices like a camera switching unit, or a quad
compressor.
1) Low
2) High
SERIES OUTPUT Terminal
During recording, when the end of the tape is reached,
the output becomes DC 5V .
SERIES INPUT Terminal
If the input becomes DC 5V for 200 msec or more,the
VCR starts series recording.
WARNING OUTPUT Terminal
1) "High"
If the error display on the display panel continues to
flash, the output becomes DC 5V. If the POWER
button is pressed, the emergency mode is released.
then the output becomes 0V.
2) "Low"
If the error display on the display panel continues to
flash, the output becomes 0V. If the POWER button is
pressed, the emergency mode is released. then the
output becomes DC 5V.
33
Time Lapse Video Cassette Recorder

Daily Inspection

The following daily inspections are recommended in
order to assure long-term and trouble-free operation of
the unit.
The daily inspections are particularly important if using
autorepeat recording.
Inspection Procedure
1
Turn on the power to the camera, TV monitor and
other connected devices.
• If the security lock is
engaged, it has to be
2
Check that the image received on the TV monitor is
released before
correct.
proceeding with the
inspection.
3
Check that the on-screen display of the date and time
• If any problem is
is correct.
discovered during the
inspection,unplug the
4
Press the REW button to rewind the recorded tape a
power cord and consult
few seconds.
your dealer.
5
Press the PLAY button and check that the playback
image is correct.
• Check in particular playback of time lapse recording
(18 or 24 hour mode)
6
Check that the recorded date and time are correct.
Time Lapse Video Cassette Recorder