Troubleshooting Guide - Security Labs SL810 User Manual

960-hour time lapse video cassette recorder
Table of Contents

Advertisement

Troubleshooting Guide

If the unit does not operate normally when you follow the instructions indicated in
the manual, please refer to the table below.
SYMPTOM
POSSIBLE CAUSE
No power.
The power cord is not correctly
connected to the wall outlet.
The unit is in timer recording stand-
by mode.
No image
The connections are not correct.
displayed on the
The power to the camera and/or
monitor TV.
monitor TV is not turned on.
The buttons do
The unit is in timer recording stand-
not respond.
by mode.
Alarm recording.
Panic recording.
The security lock(SET LOCK) is
engaged.
Unit will not go
The loaded cassette has no
into record
erasure prevention tab.
mode.
Autorepeat.
"NO" is selected for autorepeat
recording in the REC MODE SET
menu.
During autorepeat recording when
there is an alarm input, autorepeat
recording is canceled.
36
CORRECTIVE ACTION
- Connect the power cord firmly into
the walloutlet.
- This is normal, not a malfunction.
- Check that all connections are correct.
- Turn all connected devices power
on.
- Press the POWER/Timer button.
- Wait for the alarm recording to end.
- Press the STOP button for 3 seconds
to stop.
- Wait for the panic recording to end.
- Press the STOP button for 3 seconds
to stop.
- Cancel the security lock.
- Load a cassette tape with
erasure prevention tab or cover the
tab hole with adhesive tape.
- Be sure to select "YES" for
autorepeat recording.
- Set "YES" again for autorepeat
recording.
960-Hour Time Lapse Video Cassette Recorder
SYMPTOM
POSSIBLE CAUSE
Timer recording.
The date and time are not correct.
The unit is not set to timer recording
stand-by mode.
"N" is selected for the TIMER
PROGRAM SET.
Alarm recording.
"NO" is selected for alarm recording in
the ALARM REC SET menu.
Noise in the
The tracking adjustment is in the
playback picture.
wrong.
The video heads need cleaning.
The date and
"NO" is selected for the date and time
time are not
in the DISPLAY SET menu.
recorded.
The date and time go off the ON-SCREEN
by pressing the DISPLAY button.
The cassette tape
Problem with the system or tape.
cannot be ejected
Periodic Inspection and Maintenance
Periodic inspection and maintenance should be referred
to your dealer. If there is noise in the playback picture,
and it cannot be corrected using the tracking
control, it may indicated that the video heads need
cleaning. The video heads should be cleaned and
inspected every 1,000 hours. The video heads usage can
be checked using initial menu, running time.
System Down
If the unit does not function at all, try the following.
• Press the RESET button for
1
Unplug the power cord then plug it back in.
more than 5 seconds to
2
Reset the memory. (Press the RESET button. Under
perform the reset. Running
Time will not be reset.
normal conditions, do not touch the RESET button)
3
If the problem is not corrected after performing
steps 1 and 2, consult your dealer.
960-Hour Time Lapse Video Cassette Recorder
CORRECTIVE ACTION
- Set the date and time correctly.
- Press the POWER/TIMER button to
display "
" on the display panel.
- Be sure to select "Y" for the TIMER
PROGRAM SET.
- Be sure to select "YES" for alarm
recording.
- Adjust it by using the manual
tracking.
- Press the PLAY button in the
playback mode.
- Clean the video heads.
- Be sure to select "YES" for the display.
- Press the DISPLAY button to show the
date and time.
- Unplug the power cord then plug it
back in.