Heat & Glo VIENNA-I Installer's Manual page 37

Direct vent gas stove
Table of Contents

Advertisement

Installing the Stove
6. Replace rear shield.
7. Plug the fan electrical cord into the junction box
receptacle marked "FAN".
8. Connect electrical cord into the junction box - plug
the junction box cord into a 110 VAC grounded
outlet.
WARNING: DO NOT CONNECT 110-120 VAC
!
TO THE GAS CONTROL VALVE OR CON-
TROL WIRING SYSTEM OF THIS UNIT.
Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less length
of 18 A.W.G. minimum wire and connect it to the stove
ON/OFF switch pigtails.
REMOTE SWITCH PIGTAIL
(QUEUE DE COCHON DE
COMMANDE A DISTANCE)
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
(INTERRUPTEUR MURAL EN OPTION
THERMOSTAT OU COMMANDE À DISTANCE)
Figure 24.
Standing Pilot Ignition Wiring Diagram
(continued)
THERMOPILE
ON
(MARCHE)
OFF
(ARRÊT)
ON/OFF SWITCH
(INTERRUPTEUR
MARCHE/ARRÊT)
Installation
(suite)
6. Remettez l'écran arrière en place.
7. Branchez le cordon électrique du ventilateur à la
prise de la boîte de dérivation étiquetée « FAN ».
8. Branchez le cordon électrique à la boîte de
dérivation. Branchez le cordon de la boîte de
dérivation dans une prise de 110 VCA reliée à la
terre.
AVERTISSEMENT : NE BRANCHEZ PAS
!
DE COURANT ÉLECTRIQUE DE 110-120
VCA À LA VALVE DE COMMANDE DE GAZ
OU AU FILAGE DES COMMANDES DE
CET APPAREIL.
Interrupteur mural de commande
Placer l'interrupteur mural à l'emplacement voulu.
Poser un fil de 18 AWG minimum qui ne dépasse pas
7,8 m (25 ft) de longueur et le raccorder aux queues
de cochon de l'interrupteur de marche/arrêt de
l'appareil de chauffage.
Figure 24. Schéma de câblage de l'allumage
par veilleuse
37
THERMOCOUPLE
GAS VALVE
(VANNE DE COMMANDE)