To reset the AV-GAD AV-701, after the control panel response (7 8 9), you can start typing a Test Program Reset new index without waiting for the * 0 # Shunt announcement to disappear. To exit, type ‘99’ followed by the # key.
..................... 20 ETECTION EVICES (CS) ................ 20 ESTING YOUR ENTRAL TATION Troubleshooting........................21 Av-Gad Limited Warranty ...................... 23 @ All Rights Reserved to AV-GAD SYSTEMS LTD, Tel Aviv, Israel. POB 49 080 Tel-Aviv 61 104, Israel. / W7/ END_2000_2. June 02...
System Configuration Zone Index Zone Description Type Zone Description Type Installation Data Installer CS Information Programmed Telephones Phone: Phone: Mobile: Account No.: Installation date: Contact Person: Zone at Home Mode Siren Times Silent Zones Notes -------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------------...
EASY as 1,2,3. All of Av-Gad products conform to year 2000. Introduction Review this manual carefully before operating your security system.
Page 5
Bypass (Shunt) a zone Allows manual removal of one or more protected zones from the system. Day and Tamper Zone A zone programmed as a Day or Tamper Zone enables alarm from keypad's buzzer during daytime, when system is usually disarmed. The Day or Tamper zone will trigger the keypad buzzer and the zone number will flash on keypad display.
Page 6
Follower Zone (also called conditioned Zone) Follower Zone reacts instantly upon detection without previous triggering of Delayed zone. Exit delay applies to Follower zones. Hold-down Functions Holding down keys for about 2 seconds provides additional easy-to-access functions. Instant Arming Instant Arming of system. Short press on key 5 instantly arms system. Instant Zone Zone feature.
Page 7
Zone number 1, while a door protected by a magnetic contact as Zone number 3. Your installer will inform you which zones have been set up on your system. The AV-701 contains a zone index list. The AV-707 displays the zone description.
Basic Operations Arming Your System Before arming your system, close all protected doors and windows, and stop movement in areas protected by motion detectors. When all protective zones are closed, the Green Status LED stops blinking. To arm the system, enter your code. At each digit entry, the keypad sounder will beep. When the code has been entered, the Armed LED will light.
Zone Bypassing A ‘Bypassed’ zone will not cause an alarm. Zones may be bypassed to allow access to part of the protected area while other zones are armed. For example, you could bypass the zone protecting your living room. This would allow you to remain in the room, while the other zones on your system are armed.
Page 10
Instant Arming The Instant Arming feature allows you to press ‘5’ key to arm the system. This command is designed to allow user to arm the system without needing a full user code. Note: The instant arming is not recommended. This will allow the easy arming by someone who is not a regular user.
AV-701, AV-702 Keypads (LED type) AV-702 keypad contains identical keys and LED structure. The Status LED is on when all the zones are AV-GAD EASYLOADER AV-701 close. ZONE ARMED STATUS SHUNT FIRE DISPLAY The Red Armed LED is on when the system is armed.
Years 1978 through 99 as 78 to 99 Years 2000 through 2077 00 to 77 The local date is stored in system memory; adjust date after long power-failure. LED Indicators Four LEDs provide visual indication of System status, as well as confirmation of various modes.
AC Failure (Three lines) 701 keypad, indicating the power-fail event event Setting New Code for the AV-701 1. Hold down key Program 2. While four LEDs are blinking, enter the master code (default 1234) 3. If code is valid, four LEDs will stop blinking, and ‘u’ will be displayed...
4. The two Left-Most LEDs blink to indicate that the system is waiting for a new user code index (user 1 to 8) to be entered 5. Enter the code index (1 for code No. 1; 2 for code No. 2, etc.). User index will be displayed for 2 seconds, until further digits are entered (eliminate confusing of index number and code) 6.
The sounder emits sounds in the following instances: OPERATION SOUNDER RESPONSE "Pressing of any key Short confirmation beep "Hold-down functions Long confirmation beep "Faulty programming input Long beep (+ ‘E’ display) "Delayed Zone triggering 3 long beeps "Exit delay starting (if programmed) Warning beeps until the delay is over "Completion of Arm/Disarm programming One long confirmation beep...
The AV-707 keys and Hold-Down functions are identical to the AV-701 functions, you can speed up the function by pressing ‘#’ key – the ENTER key. The sounder and LEDs functions and indications are the same as described for the AV-701.
The three Rightmost LEDs start blinking; enter the Master User Code (factory default 1 2 3 4) followed by # (Enter). The upper line displays 'User Programming', the lower line is cleared and a blinking cursor appears. The Leftmost two LEDs will start blinking indicating that a ‘location’ is expected. In this case, location means ‘User Code’...
Displaying System Information Alarm Memory Display Alarms generated when the system is armed are recorded in the system's memory. Hold-down twice ‘0’ to display the zones in alarm. Shunt Concise Alarm History (Events Log): Hold-down ‘0’ to display the last alarm sequence.
Indication To do Cause ‘L’ or Low Battery on Battery is low Call for service Four LEDs are blinking AC power failure Check the premises fuse box. Call for service ‘C’ or ‘Tel. Line Fail’ Telephone line test failed Call for service Arming fail and ≡...
Shunt # LOCAL BUZZER ON and OFF Holding down keys "0" and "#" simultaneously turn on and off the buzzer in each LCD keypad. This function works in disarmed mode. Testing Your System It is recommended to test your system weekly. Perform system tests in the off- peak hours, such as early morning or late evening.
Troubleshooting PROBLEM INDICATION REMEDY System fails to Arm Keypad entries are 1. Hold down ‘9’ key until you hear a beep, when code is entered confirmed by beeps, then enter arming code at Keypad but system does not 2. Program new arming code react 3.
Page 22
PROBLEM INDICATION REMEDY Buzzer is activated Door at delayed zone Keys ‘5’ or ‘7’ have been pressed, activating for no apparent (entrance) is open or the door Chime or the Fault Find function. reason there has been detec- Arm and disarm the system. tion of movement at Hold-down ‘9’...
Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be brought within three months following the end of the warranty period. In no case shall Av-Gad be liable to anyone for any consequential or incidental damages for breach of this or any other warranty, express or implied, even if the loss or damage is caused by the seller’s own...
Need help?
Do you have a question about the EasyLoader AV-701 and is the answer not in the manual?
Questions and answers
Resetointi
To reset the AV-GAD AV-701, after the control panel response (7 8 9), you can start typing a Test Program Reset new index without waiting for the * 0 # Shunt announcement to disappear. To exit, type ‘99’ followed by the # key.
This answer is automatically generated