Turbo Air TMW-1100E Service Manual page 16

Refrigerator manufacturer turbo air
Hide thumbs Also See for TMW-1100E:
Table of Contents

Advertisement

4. Method to reduce the gap between the door seal and the oven front surface.
(1) To reduce gap located on part 'A'.
• Loosen two screws on stopper hinge top, and then push
the door to contact the door seal to oven front surface.
• Tighten two screws.
(2) To reduce gap located on part 'B'.
• Loosen two screws on stopper hinge under, and then
push the door to contact the door seal to oven front
surface.
• Tighten two screws.
NOTE : A small gap may be acceptable if the microwave leakage does not exceed 4mW/cm
14
A
B