Initializing The C; Modification Of C; C Page Table - Sony DCR-TRV9 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV9:
Table of Contents

Advertisement

Initial value
Address
NTSC
PAL
B0
Fixed data-1
B1
(Initialized data)
B2
B3
Fixed data-2
B4
FF
FF
CR clamp adj.
B5
FF
FF
CB clamp adj.
B6
FF
FF
Y clamp adj.
B7
Fixed data-1
B8
(Initialized data)
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
Fixed data-2
D1
(Modified data, copy the data built in
D2
the same model.)
D3
D4
D5
Fixed data-1
D6
D7
Fixed data-2
D8
D9
Fixed data-1
DA
(Initialized data)
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4 to FF
Table. 5-3-1
Remark
5-40
4. Initializing the C Page Data
Note: If the page C data is initialized, the following adjustments must be
performed again.
1) Modification of C page data
2) All RF block adjustments of the video system adjustments
3) Servo system adjustments
Adjusting page
C
Adjusting Address
00 to 6F
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 4, address: 02, set data: 01, and press the PAUSE
button of the adjusting remote commander.
3) Check that the data of page: 4, address: 02 changes in order of
"01", "03", "05", "00".
4) Select page: 0, address: 01, and set data: 00.
5) Perform "Modification of C Page Data".
5. Modification of C Page Data
If the C Page data has been initialized, change the data of the "Fixed
data-2" address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5) After changing the data, select page: 0, address: 01, and set
data: 00.

6. C Page Table

Note: Fixed data-1 : Initialized data. ( Refer to "4. Initializing the C Page
Data".)
Fixed data-2 : Modified data. (Refer to "5. Modification of C PAGE
Data").
Initial value
Address
NTSC PAL
00
Fixed data-1
01
Fixed data-2
02
Fixed data-1
03
04
05
06
07
08
Fixed data-2
09
Fixed data-1
0A
0B
0C
0D
0E
0F
10
11
Remark