Standard Features

Product Features
Performance
16 x 10Gb downlinks to server NICs
Each 10Gb downlink supports up to 4 FlexNICs or 3 FlexNICs and 1 iSCSI FlexHBA
Each iSCSI FlexHBA can be configured to transport Accelerated iSCSI protocol.
Each FlexNIC and iSCSI FlexHBA is recognized by the server as a PCI-e physical function device with
adjustable speeds from 100Mb to 10Gb in 100Mb increments when connected to a HP NC553i 10Gb
2-port FlexFabric Converged Network Adapter or any Flex-10 NIC and from 1Gb to 10Gb in 100Mb
increments when connected to a NC551i Dual Port FlexFabric 10Gb Converged Network Adapter or
NC551m Dual Port FlexFabric 10Gb Converged Network Adapter including NC554FLB Dual Port
FlexFabric Adapter
4 x 10Gb cross connects for redundancy and stacking
10 x 10Gb SR, LR, or LRM fiber and copper SFP+ uplinks
Supports up to 4 FlexNICs per 10Gb server connections.
Each FlexNIC is recognized by the server as a PCI-e physical function device with customizable
speeds from 100Mb to 10Gb.
Line Rate, full-duplex 600 Gbps bridging fabric
0.9 µs latency
MTU up to 9216 Bytes - Jumbo Frames
Supports up to 128,000 MAC addresses and 1000 IGMP groups
VLAN Tagging, Pass-Thru and Link Aggregation supported on all uplinks
In tunneled VLAN mode, up to 4,096 networks are supported per network uplink and server
downlink. In mapped VLAN mode, up to 1,000 networks are supported on network uplinks per Share
Uplink Set, domain or module and on server downlinks up to 162 networks are supported per 10Gb
physical port (VC v3.30 or later).
Stack multiple Virtual Connect Flex-10/10D modules with other VC Flex-10/10D, VC FlexFabric or VC
Flex-10 across up to 4 BladeSystem enclosures allowing any server Ethernet port to connect to any
Ethernet uplink
Management
Virtual Connect Manager is included with every module
HTTPS and a secure, scriptable CLI interface is ready out of the box. Easy setup and management
via the Onboard Administrator interface
SNMP v.1 and v.2, provide ease of administration and maintenance.
Port Mirroring on any uplink provides network troubleshooting support with Network Analyzers
IGMP Snooping optimizes network traffic and reduces bandwidth for multicast applications such as
streaming applications
Role-based security for network and server administration with LDAP, TACACS+ and RADIUS
compatibility
Remotely update Virtual Connect firmware on multiple modules using Virtual Connect Support
Utility 1.9.0 or greater
CLI auto-filling with TAB key
GUI and CLI session timeout for security
QoS configurable based on DOT1P and DSCP
Configurable filtering of multicast traffic
Virtual Connect Server Profiles
Create up to 4 individual FlexNICs with their own dedicated, customized bandwidth per 10Gb