10.18.1.4 Read Continuous bit
If the Read Continuous bit is set to one for the command, the device shall transfer the requested amount of data to
the host within the Command Completion Time Limit even if an error occurs. The data sent to the host by the device
in an error condition is vendor specific.
10.18.1.5 Write Continuous bit
If the Write Continuous bit is set to one for the command, and an error is encountered, the device shall complete the
request without posting an error. If an error cannot be resolved within the Command Completion Time Limit, the
erroneous section on the media may be unchanged or may contain undefined data. A future read of this area may
not report an error, even though the data is erroneous.
10.18.1.6 Streaming Logs
The Streaming Data Transfer feature set requires two error logs and one performance log. These logs are accessed
via the Read Log Ext command; the information included in the error logs is volatile and is not maintained across
power cycles, hard resets, or sleep. These error logs are 512 bytes in length and retain the last 31 errors that occurred
during any Streaming Data transfer.