TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C200 M2 server are listed in
Table 29 UCS C200 M2 Environmental Specifications
Parameter
Temperature operating
Temperature nonoperating
Altitude operating
Humidity nonoperating
Vibration nonoperating
Shock operating
Shock nonoperating
Electrostatic discharge
Acoustic
58
Minimum
10°C to 35°C (50°F to 95°F)
-40°C to 65°C (-40°F to 149°F)
0 to 3,000 m (0 to 10,000 ft.); maximum ambient temperature decreases
by 1° per 300 m
5 to 93%, noncondensing
2.2 Grms, 10 minutes per axis on each of the three axes
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes
Trapezoidal, 25 G, two drops on each of six faces
Velocity = 175 inches per second on bottom face drop
Velocity = 90 inches per second on the other five faces
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV
contact discharge without physical damage
Sound power: 54.7 dBA (5.7 Bels) at ambient temperature 23°C measured
using the Dome Method
GOST MsanPiN 001-96
Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server
Table
29.
Need help?
Do you have a question about the UCS C200 M2 and is the answer not in the manual?
Questions and answers