WASHER CONNECTIONS FOR PORTABLE MODEL WSLP1500—
ONE-FAUCET CONNECTIONS
Use the hose connector provided with the washer for a
one-faucet connection.
TO CONNECT THE WASHER:
1
REMOVE THE UNI-COUPLE
FROM INSIDE THE WASHER BASKET
COLD Water
Supply Connector
CONNECT TO WATER LINE
2
Attach the hose connector to the faucet adapter by
pulling down on the locking collar while lifting up on
the connector until it snaps into place. Make sure the
water filter provided is in place.
Hose Connector
Installation Instructions
®
HOSE
Drain Connection
Faucet Connector
Water Filter
Uni-Coupler Hose
Locking Collar
3
CONNECT TO VALVE INLET
Attach the COLD water supply connector to the COLD
water valve inlet (color BLUE). Make sure the washer is
inside the connector before tightening.
TIGHTEN CONNECTOR
4
Tighten the connector, ensuring the threads are
aligned properly for tightest fit. Inspect for kinks
or binding of the hose.
NOTE: Do not remove the plastic cap from the HOT
water inlet for uni-coupler connections as leakage may
occur.
Plastic Cap
5
CONNECT DRAIN HOSE
Attach the drain hose to the rear of the washer. Install
the clamp on the drain hose and tighten to prevent
leakage of water.