LTC 9385 Series | Instruction Manual | Installation
Recommended Maximum Cable Lengths
Models
Wire Size
2
mm
-1 (115 VAC)
1.5
2.5
4
-2 (24 VAC)
0.5
0.5
1
1.5
2.5
-4 (230 VAC)
1.5
2.5
4
1. Use the liquid-tight fitting on the left of the
housing to route the power supply cord into the
housing.
2. Allow enough cord for connection to the
terminal block; approximately, 130mm (5in.).
Strip no less than 6mm (0.24in.) and no more
than 8mm (0.31in.) of insulation away from the
wires making sure not to nick the wires.
3. A screw/terminal lug is provided for securing a
safety ground. To attach the safety grounding
wire of the power cord (green 115volt,
green/yellow 230volt), first unscrew the terminal
lug and strip and crimp the grounding wire into
the lug. Next, reattach the terminal lug to the
rail assembly using the M4 x 10 screw and lock
washer provided. See FIGURE 8.
FIGURE 8 Securing the Ground Wire
Bosch Security Systems | January 26, 2005
Distance
AWG
meters
feet
16
1000
3280
14
1600
5250
12
2500
8200
22
10
30
20
15
50
18
25
80
16
40
120
14
70
210
16
4000
13000
14
6400
21000
12
10000
32800
4. Connect both the line and neutral wires of the
power cord to the terminal block. Make sure
the line and neutral wires are connected to the
correct positions on the terminal block that are
across from the appropriate colored wire. See
FIGURE 9.
FIGURE 9 Attaching Line and Neutral Wires
5. Pull any excess cord through the liquid-tight
fitting and tighten the flex fitting to 8.5N-m to
9.0N-m (75in. lb to 80in. lb). This torque rating
is approximately 1 to 1 1/2 turns past the point
that the fitting starts to grip the cord. Failure to
do so will result in water damage to all
electronic parts. Use a tie wrap (included) to
provide strain relief on the power cord at the
exit point (inside the unit).
Securely tighten all fittings to ensure a liquid-
tight seal. Not doing so could damage the
camera, the housing, or both.
5.8.2 Camera Power Connections
LTC 9385/60 Housings
These housings are to be connected to 115VAC, and
are designed for use where site power is 115volts. The
LTC 9385/60 housings should only be used with
115volt cameras. The integral heater/defogger
requires 115volts. The housing is shipped with the
heater/defogger connected to the terminal block.
Installing a 115 volt camera into the LTC 9385/60
housing simply requires the camera's line cord to be
plugged into the NEMA 5-15R receptacle provided.
See FIGURE 10.
EN | 11