Troubleshooting - Schwinn 130i Upright Bike Assembly Manual

Assembly and owner's manual
Hide thumbs Also See for 130i Upright Bike:
Table of Contents

Advertisement

Condition/Problem
No display/partial display/
unit will not turn on
Unit operates but Contact
HR not displayed
Console displays "E2" error
code
No speed/RPM reading,
Console displays "Please
Pedal" error code
Console shuts off (enters
sleep mode) while in use
Things to Check
Check electrical (wall)
outlet
Check connection on
console
Check data cable integrity
Check data cable
connections/orientation
Check console display for
damage
Console Display
HR cable connection at
Console
Sensor grip
Dry or calloused hands
Handlebar
Check data cable integrity
Check data cable
connections/orientation
Console Electronics
Check data cable integrity
Check data cable
connections/orientation
Check magnet position
(requires shroud removal)
Check Speed Sensor
(requires shroud removal)
Check electrical (wall)
outlet
Check connection on
console
Check data cable integrity

TroublesHooTIng

Make sure unit is plugged into a functioning wall outlet.
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check for visual sign that console display is cracked or otherwise
damaged. Replace Console if damaged.
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact your local
distributor for further assistance.
Be sure cable is connected securely to Console.
Be sure hands are centered on HR sensors. Hands must be kept
still with relatively equal pressure applied to each side.
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream (heart rate cream) can help make
better conduct. These are available on the web or at medical or
some larger fitness stores.
If tests reveal no other issues, Handlebars should be replaced.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
If tests reveal no other issues, contact your local distributor for
further assistance.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Magnet should be in place on pulley.
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Make sure unit is plugged into a functioning wall outlet.
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
All wires in the cable should be intact. If any are cut or crimped,
replace cable.
Solution
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents