N1010A FlexDCA and 86100A/B/C/D
Firmware Release Notes
• Support for the N1012A OIF CEI Compliance 3.0 Application and N1019A User
Defined Application Tool. The new menu also supports user- added shortcuts to
files and Windows applications.
• FlexDCA now includes the ability to take into account the effect of external
devices such as attenuators or transducers. With this feature, FlexDCA will report
waveform and measurement results referenced to the input of the external device
instead of the input of the oscilloscope channel. Additionally, if you have
configured external attenuator or transducer settings in the 86100C/D firmware,
they will be transferred to FlexDCA when using "Transfer Basic" on connection to
the DCA.
• New copy- to- clipboard buttons on the shortcut menus for pasting waveform
images or measurement data to external applications.
• Ability to find a bit sequence in a pattern waveform.
• Ability to select one of four color schemes for displaying color- grade persistence
waveforms. This includes a color scheme that matches the classic 86100A/B/C/D
firmware.
• Ability to select color or monochrome display of gray- scale persistence waveforms.
• The remote SCPI interface is fully supported on 64- bit operating systems.
• The bandwidth of a differential signal can be configured from a single drop- down
in the GUI.
• The message area can now be "docked" so that it is permanently visible. To enable
this feature, access the "Display Setup" dialog from the "Setup" menu. Near the
bottom of the "Appearance" tab is a checkbox called "Dock Message Area".
General Defects Fixed
• Changed the default trigger bandwidth on the 86100D- STR frame from "Filtered
Edge" to "Standard Edge".
• The waveform save feature will only allow you to save waveforms that are
currently displayed. Previously, waveforms that had been acquired but not
displayed could also be saved, which made it easy to accidently save the wrong
waveform.
• Fixed the remote command ":DISK:SIMage:SINClude" in eye mode.
• Fixed a defect that caused Precision Timebase Synchronization to take a very long
time to complete when a PRBS 23 pattern was in use.
Common Programming Commands
• *IDN? (revised)
:ACQuire Subsystem Programming Commands
• :ACQuire:RLENgth:AUTo (deprecated)
• :ACQuire:RLENgth:MODE (new)
• :ACQuire:SPBit:AUTo (deprecated)
• :ACQuire:SPBit:MODE (new)
:CHANnel Subsystem Programming Commands
• :CHANnel:ATTenuator:DECibels (new)
• :CHANnel:ATTenuator:RATio (new)
• :CHANnel:ATTenuator:RESet (new)
• :CHANnel:ATTenuator:STATe? (new)
• :CHANnel:TRANsducer:GAIN (new)
• :CHANnel:TRANsducer:OFFSet (new)
• :CHANnel:TRANsducer:STATe (new)
• :CHANnel:TRANsducer:UNITs (new)