MAINTENANCE

PRESSURE REGULATOR

For best results with the pressure regulator, we recommend that you clean and lubricate
the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.
1. Turn unit off before lubricating.
2. Remove cap, spring and spring retainer plate.
3. With fingertips remove piston and u-cup.
4. Wipe piston and u-cup clean of any film or scale.
5. Lubricate the piston and u-cup with Superlube.
6. Reassemble regulator.
7. With pump ON, re-adjust pressure regulator for normal operation.
LUBRICATE U-CUP WITH SUPERLUBE MONTHLY.
U-CUP
SPRING RETAINER PLATE
OUT
PISTON
IN
SPRING
CAP
(GOLD - 125 PSI)
CHEYENNE 86038870 03/14/07