Download Print this page
NAPCO IQ Profiler Installation Instructions Manual
NAPCO IQ Profiler Installation Instructions Manual

NAPCO IQ Profiler Installation Instructions Manual

Advanced profiling technology passive infrared sensor
Hide thumbs Also See for IQ Profiler:

Advertisement

Quick Links

TM
Advanced Profiling Technology
PASSIVE INFRARED SENSOR

INSTALLATION INSTRUCTIONS

Napco Security Systems, Inc.
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
R
WI1017 08/00
1

Advertisement

loading

Summary of Contents for NAPCO IQ Profiler

  • Page 1: Installation Instructions

    Advanced Profiling Technology PASSIVE INFRARED SENSOR INSTALLATION INSTRUCTIONS Napco Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 WI1017 08/00...
  • Page 2 Now it just takes a minute and a screwdriver to install the smart microprocessor-based PIR that profiles targets against a built-in library of 1200+ false alarm and alarm sources for verified detection -- NAPCO’s IQ Profiler Sensor! 50 lb. Pet Immunity (22.7kg) * Maximum Range: 50 x 50 Feet (15.2m x 15.2m)
  • Page 3: Specifications

    SPECIFICATIONS Coverage (l x w): 50' x 50' (15.2m x 15.2m) at 20°C (68°F), typical. (with High Sensitivity Jumper “SEN” installed) 30' x 35' (9.1m x 10.6m) at 20°C (68°F), typical. (with Normal Sensitivity) Operating Temperature: -10° to +50°C (14°F to 122°F) Mounting: Wall or corner, 6.5’...
  • Page 4 Bi-Optic Contour Case and Dual focal lenses provide exceptional distance profiling: “Far Field Lens” allows for detection of large objects and ignores small targets nearby “Near Field Lens” allows for discrimination of small targets nearby NAPCO 10/00 Pats. Pending IQ Profiler is a trademanrk of NAPCO...
  • Page 5 Locating the Detector Corner mounting is preferred as it provides the best overall coverage. Choose a corner where the path of an intruder will most likely cross beams, as opposed to walking towards or away from them. This lens is intentionally made with an 85 degree angle of view, to help prevent curtains on windows from being in detection zones.
  • Page 6 50 lbs. and less than 24” tall. Several small cats are acceptable. If you have three or more large ones, we recommend that the NAPCO C200AP dual technology sensor be used. Mount the unit at a height of 7 ft. Following are 2 installation techniques, one for small pets and one for larger pets.
  • Page 7 Large Pet Avoidance The IQ Profiler can be configured to avoid detection of pets up to 50 pounds and less than 24” tall. Remove or mask the small look down lens just below the PIR sensor. Configured in this manner, the IQ Profiler will allow a larger pet to freely move about, but still retain the sensitivity required to detect an intruder.
  • Page 8 Preparing to Mount the IQ Profiler Insert screwdriver into slot on bottom of unit to remove top of housing Remove the circuit board from the housing by gently pushing outward on the PC board height index tab which is located on the left edge of the housing.
  • Page 9 nstall uick Corner Mounting Instructions The IQ Profiler incorporates a patented nstall uick Corner Mounting feature which allows quick corner mounting on standard sheet rock (drywall) surfaces. Firmly hold the base of the housing against the corner of the wall in the location in which it is to be mounted. Insert a large bladed screwdriver into the Install Quick corner mounting slot and twist clockwise approximately 45 degrees (1/8 turn).
  • Page 10 Wiring the IQ Profiler using the nstall uick Terminals The IQ Profiler incorporates innovative nstall uick wiring terminals which allow wiring within seconds. Strip approx. 1/4” of insulation from the end of each wire, insert into the top of the terminal and press the lever down to secure the wire.
  • Page 11 Mounting the IQ Profiler to a Flat Wall To mount the IQ Profiler on a flat wall, push through any of the 4 recesses marked “flat wall mount” on the base detail diagram. Swivel Bracket Mounting the IQ Profiler The optional SVL2 Swivel Bracket Kit may be used to mount the IQ Profiler units against a wall or under a ceiling and provides vertical and horizontal tilting, To mount the SVL2 to the IQ Profiler, follow the detailed instructions...
  • Page 12 DETAIL TROUBLE ALARM OUTPUT OUTPUT TAMPER Remove Jumper Tamper Switch to Disable LED Temperature Sensor Mounting Height Index Walk Test LED PIR Sensor Sensitivity Jumper Look Down Lens ON = High Sensitivity OFF= Normal IQ PROFILER CIRCUIT BOARD DETAIL...
  • Page 13 CONFIGURING THE IQ PROFILER LED Disable Jumper To prevent the walk test LED from turning on, remove the jumper from the pins labeled LED DISABLE. Removing this jumper will not affect the flashing of the LED on self test failure. Sensitivity Setting (SEN Jumper) The unit is shipped with no jumper in this position.
  • Page 15: Napco Limited Warranty

    NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user.
  • Page 16 NAPCO is not an insurer of either the property or safety of the user's family or employees, and limits its liability for any loss or damage including incidental or consequential damages to NAPCO's original selling price of the product regardless of the cause of such loss or damage.