NAPCO GEM-EZM4/8 Addendum

Zone expansion module for the gem-p1664 control panel

Advertisement

Quick Links

R
333 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
For Technical Service, (800) 645-9440
Publicly traded on NASDAQ
Symbol: NSSC
© NAPCO 2005
DESCRIPTION
The capacity of the GEM-P1664 control panel may be expanded through the use of a GEM-EZM4/8 Zone Expansion Module. Each
GEM-EZM4/8 module provides up to 16 additional zones, and may be configured in a number of methods: 4 zones, 8 zones, 12 zones
or 16 zones. Using any of these configurations, several GEM-EZM4/8 modules may be combined as necessary to supply the required
number of zones to the GEM-P1664 control panel. Refer to the GEM-P1664 Installation Instructions and GEM-P1664 Programming
Instructions for wiring requirements. Note: Although the GEM-EZM4/8 may also be used with the GEM-P816 and GEM-P1632 control
panels, the features described in this addendum apply only to the GEM-P1664.
WIRING
Wire the expansion zones to the module and the module to the control panel in accordance with the wiring diagrams shown using
wire no thinner than #22AWG. Install EOL (end-of-line) resistors on all zones even if one or more zones are not used. NOTE: The
addition of Zone Expansion Modules will reduce the amount of current available by 60mA at the control panel's Auxiliary Power Output
terminals.
GEM-EZM4/8 ZONE EXPANSION MODULE
9 10 11 12
GEM-P1664
CONTROL PANEL
ZONE EXPANSION MODULE
GEM-P1664 Control Panel
SPECIFICATIONS
MAXIMUM LOOP RESISTANCE
Current
(
Nominal
Standard Zone
Primary Zones in
Voltage
Configuration
Zone Doubled
)
12VDC
Configuration
300 Ohm
100 Ohm
60 mA
GEM-EZM4/8 Wiring Diagram
ADDENDUM
GEM-EZM4/8
Secondary Zones in
Zone Doubled
Configuration
100 Ohm
for the
WI1418A 5/05
1

Advertisement

loading

Summary of Contents for NAPCO GEM-EZM4/8

  • Page 1 The capacity of the GEM-P1664 control panel may be expanded through the use of a GEM-EZM4/8 Zone Expansion Module. Each GEM-EZM4/8 module provides up to 16 additional zones, and may be configured in a number of methods: 4 zones, 8 zones, 12 zones or 16 zones.
  • Page 2 SERIES ZONE AND LOOP SUPERVISION CONFIGURATION (1 EZM-4 ZONES) Loop supervision with For "Series Zone and Loop Supervision one contact using a (–) Configuration": 2.2K across the con- 1. Do not program NO EOLR (by zone) tact and a 2.2K EOL 2.
  • Page 3 You can then support this total by adding the appropriate number of GEM-EZM4/8 modules which can be configured as 4, 8, 12 or 16 zone modules. The number of modules required is a function of the number of zones required as well as the configuration of the EZM's.
  • Page 4: Napco Limited Warranty

    NAPCO will, within said period, at its option, repair or replace any In no event shall NAPCO be liable for an amount in excess of product failing to operate correctly without charge to the original NAPCO's original selling price of the product, for any loss or damage, purchaser or user.

This manual is also suitable for:

Gem-ezm8Gem-ezm4