NAPCO ADVANCED ADAPTIVE C-200AP Installation Instructions Manual
NAPCO ADVANCED ADAPTIVE C-200AP Installation Instructions Manual

NAPCO ADVANCED ADAPTIVE C-200AP Installation Instructions Manual

30" range pir/microwave technology sensor
Hide thumbs Also See for ADVANCED ADAPTIVE C-200AP:

Advertisement

Quick Links

ADVANCED ADAPTIVE
PIR/MICROWAVE
TECHNOLOGY
SENSOR
TM
C-200AP
C-200APC
U.S. PATENT NO. 5,331,308
INSTALLATION INSTRUCTIONS
30' RANGE
30' RANGE
WI865A 8/97

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO ADVANCED ADAPTIVE C-200AP

  • Page 1 INSTALLATION INSTRUCTIONS ADVANCED ADAPTIVE PIR/MICROWAVE C-200AP 30’ RANGE TECHNOLOGY C-200APC 30’ RANGE SENSOR U.S. PATENT NO. 5,331,308 WI865A 8/97...
  • Page 2: Table Of Contents

    CHOOSING A SUITABLE LOCATION ....7 © NAPCO 1997. All Rights Reserved Napco Security Systems, Inc., 333 Bayview Avenue, Amityville, New York 11701 Sales, Repairs & Technical Service (Toll Free): (800) 645-9445...
  • Page 3: General Description

    40 pounds. (For larger pets, a battery must be fully recharged within 24 hours and provide 4 hours of standby conventional Pet-Alley Lens is provided.) The C-200AP uses a Form-A alarm operation.
  • Page 4: Ordering Information

    ORDERING INFORMATION Microwave circuit supervision. C-200AP Dual Technology Microwave/PIR Detector (Form-A Relay) 4-Pulse Mode for hostile environments. C-200APC Dual Technology Microwave/PIR Detector (Form-C Relay) Quick-Response Mode while disarmed. SVLBKT Swivel Bracket Kit Form-A or Form-C relay version available. LENS817 Pet-Alley Lens Trouble Output.
  • Page 5: Pir Zone Dimensions

    Thus the two complementary technologies provide an inherent immunity to DETECTION PATTERNS false alarms. Dual technology is ideal for use in hostile environments. Since Figure 2 illustrates maximum PIR and microwave detection patterns super- both must trip simultaneously to cause an alarm, installation is easier and imposed on each other.
  • Page 6: Standard Lens

    STANDARD LENS Fig. 2. Standard This model uses a standard lens that yields the 18-zone, 40-beam pattern lens patterns illustrated in Fig. 2. The coverage pattern is adjustable, within limits, both showing maxi- vertically and horizontally (see ADJUSTMENTS: Aiming the Beams for mum recom- detailed adjustment procedures).
  • Page 7: Installation

    INSTALLATION (1) the size and shape of the area to be protected. In a large or irregularly- shaped area, the use of two or more units may be advisable for volumetric IMPORTANT! For optimum results in pet applications, coverage; Mount the unit at 7–8’, adjust the microwave gain control to the (2) the PIR lens installed (see ORDERING INFORMATION for available minimum setting required to detect a intruder.
  • Page 8: Changing The Lens

    CHANGING THE LENS 4 and connect as follows: The lens is “sandwiched” between the front Power (Terminals 1 [+] & 2 [–]). Apply 12Vdc to Terminals 1 [+] and 2 [–]. case and a Lens Support Insert, which also The power source may be regulated or unregulated. Power should be serves to hold the LED jewel in place.
  • Page 9: Adjusting The Coverage Area

    that the panel is armed. Trouble (Terminal 6). This is an open-collector output that produces an active low to signal a trouble condition. ADJUSTING THE COVERAGE AREA Self Test The self-test diagnostic simulates motion and tests the PIR sensor, amplifier and related PIR circuitry, the microwave transmitter, receiver, and associated microwave circuitry.
  • Page 10 1. Check that lens is installed smooth side out, grooved side in. 2. To aim beams straight out, set Notch “B” to left edge of top lens guide. 3. To aim beams 6° to the right, set Notch “A” to left edge of top lens guide. 4.
  • Page 11: Testing The Coverage Area

    an intruder must cross several beam pairs to trip an alarm. To lock the unit and, if necessary, altered to accommodate local environmental conditions into the 4-Pulse Mode while maintaining adaptive microwave operation, install (within the coverage area). Satisfactory checks may be made using the both the PIR jumper and the MW jumper.
  • Page 12 with the ALARM jumper installed. Zone Masking Test for environmental disturbances. If a workable solution cannot be achieved using the above technique, selective zone masking will be required. This will deactivate a problem zone Note: The following test is applicable to the PIR section only. There are no in order to preserve reliable Fig.
  • Page 13: Completing The Installation

    COMPLETING THE INSTALLATION jumpers must be installed.) With the ALARM jumper (or PIR & MW numpers) The jumper must be in either the installed, the LED will indicate a condition that would cause an alarm if the ALARM position or the LED position for system were armed.
  • Page 14: Optional Lenses

    OPTIONAL LENSES possibility of pets (dogs, cats, etc.) or pests (mice, rats, etc.) from causing an alarm. Note: Mount the unit at a height of 6’ for this application. Pet Alley Lens (LENS817) A pet alley is an insensitive area above floor level that will reduce the Fig.
  • Page 15: Advanced Features

    ADVANCED FEATURES (Where available) Quick Response Mode If Terminal 5 is connected to the Status Terminal (Arm Lug) of the control Trouble Output panel, the sensor will provide a quicker response time while the panel is Terminal 6 is an open collector Trouble output; a trouble condition is disarmed.
  • Page 16: Wiring Diagrams

    Fig. 10. Trouble and Status configuration: alarm sent on trouble condition while armed (four wires; for clarity, power wires not shown).
  • Page 17 Fig. 10. Trouble and Status configuration: alarm sent on trouble condition while armed (four wires; for clarity, power wires not shown).
  • Page 18 NOTES...
  • Page 19 IN NO CASE SHALL NAPCO BE LIABLE TO to modify, to change, or to assume for it, any other warranty or liability concerning its products.
  • Page 20 NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY NAPCO is not an insurer of either the property or safety of the user’s family TESTED WEEKLY. or employees, and limits its liability for any loss or damage including incidental Warning: Despite frequent testing, and due to, but not limited to, any or all or consequential damages to NAPCO’s original selling price of the product...

This manual is also suitable for:

Advanced adaptive c-200apc

Table of Contents