Programming Thermostat Schedules - Carrier 33CS220-LA Owner's Manual

Commercial programmable thermostat
Table of Contents

Advertisement

Hold down the buttons to quickly move through the time
display. The AM and PM annunciators will automatically
change. To scroll through by hours only, press and hold down
the Fan button while pressing the UP or DOWN ARROW
buttons. To ensure the schedules are properly followed, make
sure that AM or PM is correct for the time chosen. When the
correct time is shown, press the Mode/Next button to modify
the day of the week. The current day will blink on and off.
Press the UP ARROW and DOWN ARROW buttons until
the correct day is shown. Press the Set Clock button again
to exit the Set Time mode.
Programming Thermostat Schedules —
fore programming the thermostat, plan the thermostat daily
schedule. The schedule is divided into 7 days (Monday through
Sunday). Each day can have 2 (Occupied 1, Unoccupied),
3 (Occupied 1, Occupied 2, Unoccupied), or 4 (Occupied 1,
Occupied 2, Occupied 3, Unoccupied) time periods. Each
occupied time period has a start time, stop time, heating set
point and a cooling set point. The unoccupied time period
has a heating set point and a cooling set point. The unoc-
cupied time period is active whenever an occupied time
period is not active. Fill in Table 1 below as an aid to pro-
gramming the daily schedules.
NOTE: When the sensor detects light (the space is occu-
pied), the thermostat will enter Occupied 1 mode. If the room
is dark, the thermostat will follow its programmed schedule.
The Occupied 1 schedule should be turned OFF to keep
the thermostat from entering Occupied 1 while the room is
unoccupied. If the Occupied 1 schedule is turned ON, the
thermostat will enter Occupied 1 per the schedule regardless
of light activation. The Occupied 1 set points are used as the
heating and cooling set points during light activation. The
Unoccupied set points should be used as non-work hour
set points (before 8:00 AM and after 5:00 PM) when using
light activation. For times when the building is unoccupied
during work hours (Monday through Friday, 8:00 AM to
5:00 PM), the Occupied 2 schedule should be turned ON,
and can be used for moderate energy savings with set points
of 80 F for cooling and 65 F for heating.
PROGRAMMING MODE — To program the daily sched-
ules, perform the following procedure:
1. Enter programming mode by pressing the Program but-
ton. The Occupied 1 annunciator will appear on the ther-
mostat display. See Fig. 5. Use the UP ARROW and
DOWN ARROW buttons to set the maximum number
of Occupied periods available. The thermostat can be
DAY
OF THE
WEEK
Start / Stop / Heat / Cool
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
NOTE: The cooling temperature set point must be higher than the heating temperature set point.
Table 1 — Daily Schedule Planner
Occupied 1
Start / Stop / Heat / Cool
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
set to 1, 2, or 3. After the number of Occupied periods
has been selected, press the Mode button.
2. The cooling set point for Occupied 1 will be displayed.
Use the UP ARROW and DOWN ARROW buttons
to raise or lower the cooling set point until the desired
temperature is shown. The range of acceptable values is
35 to 99 F (1 to 37 C). Press the Mode button to con-
tinue. See Fig. 5.
3. The heating set point for Occupied 1 will be displayed.
Use the UP ARROW and DOWN ARROW buttons to
raise or lower the heating set point until the desired tem-
perature is shown. The range of acceptable values is
Be-
35 to 99 F (1 to 37 C). Press the Mode button to con-
tinue. See Fig. 5.
Fig. 5 — Setting Occupied 1 Set Points
4. The cooling set point for Unoccupied will be displayed.
Use the UP ARROW and DOWN ARROW buttons to
raise or lower the cooling set point until the desired tem-
perature is shown. The range of acceptable values is
35 to 99 F (1 to 37 C) or ''OF'' (no unoccupied cool-
ing). Press the Mode button to continue.
5. The heating set point for Unoccupied will be displayed.
Use the UP ARROW and DOWN ARROW buttons to
raise or lower the heating set point until the desired tem-
perature is shown. The range of acceptable values is
35 to 99 F (1 to 37 C) or ''OF'' (no unoccupied heating).
Press the Mode button to continue.
6. The day of the week will be shown. Use the UP
ARROW and DOWN ARROW buttons to change the
day of the week until the desired starting day is shown.
Possible choices are M (Monday) through S (Sunday).
Press the Mode button when the desired day is shown.
SCHEDULE
Occupied 2
Start / Stop / Heat / Cool
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
3
Occupied 3
Unoccupied
Heat / Cool
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

Hide quick links:

Advertisement

Table of Contents
loading