Carrier 33CS220-LA Owner's Manual
Carrier 33CS220-LA Owner's Manual

Carrier 33CS220-LA Owner's Manual

Commercial programmable thermostat

Advertisement

CONTENTS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Thermostat Display . . . . . . . . . . . . . . . . . . . . . . . .
Heat or Cool Indicator . . . . . . . . . . . . . . . . . . . . .
Thermostat Front Panel Buttons . . . . . . . . . . . .
Thermostat Programming Buttons . . . . . . . . . .
Set Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5
Auto-Changeover . . . . . . . . . . . . . . . . . . . . . . . . . .
Light-Activated Operation . . . . . . . . . . . . . . . . . .
Two-Stage Operation . . . . . . . . . . . . . . . . . . . . . .
Clock Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Emergency Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electric Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Holiday Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT: Read entire instructions before program-
ming the thermostat.

GENERAL

Carrier's 7-day, commercial, programmable thermostats
are wall-mounted, low-voltage thermostats which maintain
room temperature by controlling the operation of an HVAC
(heating, cooling and ventilation) system. Separate heating
and cooling set points and auto-changeover capability allow
occupied and unoccupied programming schedules for
energy savings.
All thermostats allow up to 3 occupied and one un-
occupied time/temperature setting to be programmed per
24-hour period. Each thermostat stores programs for
7 independent days. Batteries are not required. During power
interruption the internal NEVERLOST™ memory stores pro-
grams for an unlimited time.
IMPORTANT: The thermostat has a configurable security
level. If certain functions are not available (changing set
points, changing programming schedules), the thermostat
security level may be configured to exclude those func-
tions. Call the installer to reconfigure the security level.
A light sensor is provided on the thermostat for light
activation. When the sensor detects light (the space is
occupied), the thermostat will enter into Occupied 1 mode.
If the room is dark, the thermostat will follow its pro-
grammed schedule.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1
4
PC 111
Tab
11a 13a
Owner's Manual
Part Number 33CS220-LA
Page
1
1
1
1
2
2
3
4
4
5
5
5
5
5
Catalog No. 533-332
Printed in U.S.A.

Programmable Thermostat

CONFIGURATION

Thermostat Display -

located in the center of the thermostat. See Fig. 1. The fol-
lowing information can be displayed on the screen:
• mode (OFF, HEAT, COOL, AUTO, or PROGRAM ON)
• fan setting (FAN ON or blank)
• override indication
• room temperature
• desired temperature
• service filter indicator
• time of day
• day of the week
• schedule period (Occupied 1, 2, or 3; or Unoccupied)
• setup indicator (programming mode)
• lock indicator
• start/stop indicator (schedule period program mode)
Fig. 1 - Thermostat Display

Heat or Cool Indicator -

is located on the bottom left cover of the thermostat. See
Fig. 2. The light will be red if the thermostat is in Heating
mode. The light will be green if the thermostat is in Cooling
mode.
Thermostat Front Panel Buttons -
stat has buttons on the front cover which are used to raise or
lower the desired set point and override the current program.
See Fig. 2.
SET POINT BUTTONS - The UP ARROW and DOWN
ARROW buttons will raise or lower the current desired tem-
perature set point. If the thermostat is in AUTO mode, press-
ing the UP ARROW or DOWN ARROW buttons will adjust
Form 33CS-6SO
Pg 1
33CS
Commercial
The thermostat display is
A Heat or Cool indicator
The thermo-
2-98
Replaces: New

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 33CS220-LA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 33CS220-LA

  • Page 1: Table Of Contents

    • start/stop indicator (schedule period program mode) IMPORTANT: Read entire instructions before program- ming the thermostat. GENERAL Carrier’s 7-day, commercial, programmable thermostats are wall-mounted, low-voltage thermostats which maintain room temperature by controlling the operation of an HVAC (heating, cooling and ventilation) system. Separate heating...
  • Page 2: Thermostat Programming Buttons

    both the heating and cooling set points. Pressing the UP ARROW or DOWN ARROW buttons in Cooling mode will adjust only the cooling set points. Pressing the UP ARROW or DOWN ARROW buttons in Heating mode will adjust only the heating set points. The UP ARROW and DOWN ARROW buttons are also used in Programming mode.
  • Page 3: Programming Thermostat Schedules

    Hold down the buttons to quickly move through the time set to 1, 2, or 3. After the number of Occupied periods display. The AM and PM annunciators will automatically has been selected, press the Mode button. change. To scroll through by hours only, press and hold down 2.
  • Page 4: Operation

    7. The Start Time for Occupied 1 will be displayed. Use 12. After all the times and set points for each day have been the UP ARROW and DOWN ARROW buttons to raise entered, press the Program button to finish entering the or lower the time until the desired Start Time is shown.
  • Page 5: Two-Stage Operation

    Two-Stage Operation — Electric Heat The second stage of heat or — When the Electric Heat option in the cool is turned on when the first stage has been on for a mini- advanced set up is set to ON (configured by installer), the mum of 2 minutes and the temperature differential from the thermostat will turn on the fan immediately any time there set point is equal to or greater than the set point plus the...
  • Page 8 Copyright 1998 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 PC 111 Catalog No. 533-332 Printed in U.S.A. Form 33CS-6SO Pg 8 2-98 Replaces: New...

Table of Contents