Carrier EDGE Pro 33CS2PPRH-01 Installation Instructions Manual

Carrier EDGE Pro 33CS2PPRH-01 Installation Instructions Manual

Commercial
Hide thumbs Also See for EDGE Pro 33CS2PPRH-01:

Advertisement

Part Numbers 33CS2PPRH-01 and 33CS2PP2S-01
IMPORTANT: Read entire instruction before installing
CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
PACKAGE CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION CONSIDERATIONS . . . . . . . . . . . . . .1,2
Control Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Outdoor Temperature Sensor . . . . . . . . . . . . . . . . . . . . 2
Remote Indoor Temperature Sensor. . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Thermostat Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Wiring Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Two-Piece Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Single-Piece Installation . . . . . . . . . . . . . . . . . . . . . . . . . 5
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
(33CS2PPRH-01 Model Only). . . . . . . . . . . . . . . . . . . . 5
CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
To Enter and Exit Configuration Mode. . . . . . . . . . . . 5
Configuration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SYSTEM START-UP AND CHECKOUT . . . . . . . . . .9,10
Installer Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Final Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Default Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
and Holiday Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
(33CS2PPRH-01 Only). . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Holiday. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10,11
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Equipment On Indicators. . . . . . . . . . . . . . . . . . . . . . . . 11
Humidification and Dehumidification
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Auto Changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Emergency Heat Mode . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dry Contact/Economizer Input . . . . . . . . . . . . . . . . . . 11
TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . 11-19

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Fol-
low all local electrical codes during installation. All wiring
must conform to local and national electrical codes. Improper
wiring or installation may damage sensor.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53330010-01
Installation Instructions
Printed in U.S.A.
Commercial Thermostat
Recognize safety information. This is the safety alert sym-
bol
. When the safety alert symbol is present on equipment
or in the instruction manual, be alert to the potential for person-
al injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.

GENERAL

Carrier's 7-day, 5/2-day, or 1-day programmable commer-
cial thermostat control is a wall-mounted, low-voltage control
which provides temperature control in either a single unit or a
two-piece unit. The 33CS2PPRH-01 will provide both temper-
ature and humidity control. In two-piece configuration, the re-
lays are located near the equipment and a two-wire connection
is used between the display module (user interface) and the
equipment control module. Single-piece installation requires
more wiring and results in a higher profile. The thermostat has
no need for batteries to store user-configured settings in memo-
ry. During power loss its internal memory saves settings for un-
limited time, and the clock continues to run for at least
24 hours.
In the programmable configuration, different heating and
cooling set points and times are programmable for 4 periods
per day or 2 periods per day. Programming can be done for
7 days per week, 5 and 2 days per week, or 1 day. The pro-
grammable control can also be user configured as a non-
programmable control.

PACKAGE CONTENTS

1 - Display module
1 - Stand-off for equipment control module
2 - Screws and anchors
1 - Pigtail
1 - Equipment control module with cover

INSTALLATION CONSIDERATIONS

There are two types of thermostats available. The
33CS2PP2S-01 provides temperature control and the
33CS2PPRH-01 provides both temperature and humidity con-
trol. Both models can be configured for air conditioner or heat
pump installations and may be configured as non-programma-
ble if user desires.

Control Configuration -

stalled in one of two configurations. The thermostat may be in-
stalled as a single-piece or it may be split into two pieces and
mounted in separate locations.
Form 33CS-65SI
Pg 1
®
EDGE
Pro
Programmable
The thermostat can be in-
8-08
Replaces: New

Advertisement

Table of Contents
loading

Summary of Contents for Carrier EDGE Pro 33CS2PPRH-01

  • Page 1: Table Of Contents

    INSTALLATION ....... . . 2-5 Carrier’s 7-day, 5/2-day, or 1-day programmable commer- Thermostat Location .
  • Page 2: The Thermostat

    NOTE: Only Carrier sensors (part no. ZONECCORRS01) may be used for standard space temperature sensor averaging. Sensors must be used as a single sensor, 4 sensors, or 9 sen- sors, with total sensor wiring not to exceed 1,000 feet.
  • Page 3 a33-9166 Fig. 5 — Pigtail Connection 10. Push any excess wire into wall and against mounting base. Seal hole in wall to prevent air leaks. Leaks can af- a33-9164 fect operation and cause incorrect temperature and/or hu- midity measurement. Fig. 3 — Mounting Plate Installation 11.
  • Page 4 16. Match and connect equipment wires to proper terminals of each connector block, being careful not to over tighten the screws. Correct polarity must be observed when con- necting the two wires from the equipment control module to the display module mounting base. If wires are con- nected incorrectly, the display module will not operate.
  • Page 5: Single-Piece Installation

    transformer for power, the breakout jumper should remain in- For single-piece installa- Single-Piece Installation — tact. For applications using two 24-VAC transformers, the tion, perform the following procedure. breakout jumper must be broken because possible voltage dif- 1. Turn off all power to equipment. ferences between the two transformers could cause irregular 2.
  • Page 6: Configuration Options

    (Lr). Settings are L, r, Lr. The default is L Unused (local). Reversing Valve NOTE: Only Carrier sensors (part no. ZONECCORRS01) Adjustable Set Point Deadband may be used for standard space temperature sensor averaging. Smart Recovery Sensors must be used as a single sensor, 4 sensors, or 9 sen- Space Temperature Offset Adjustment sors, with total sensor wiring not to exceed 1,000 feet.
  • Page 7 non-programmable. Allowable selections are OF (off), 30, 60, set point to prevent rapid on/off cycling of the DEHUM output. and 90. The default is 90. When configured for dehumidification, the Rc terminal must be connected to one of the dry contact terminals. This provides OPTION 13 —...
  • Page 8 The default is OF (off). When 2 is displayed, the installer will then choose the end date for daylight savings time (Fall) which will be a month OPTION 24 — PROGRAMMABLE/NON-PROGRAM- range of 7 to 12. MABLE — This selection allows the installer to configure the thermostat as either programmable (P) or non-programma- To activate the function, the installer changes the “2”...
  • Page 9: System Start-Up And Checkout

    When set to OF, the thermostat set points can not be over- SCHEDULE icon is turned on. The default schedule is shown ridden by the user. in Table 2. Pressing the Schedule button will cycle the triangle icon through the FOLLOW SCHEDULE, HOLD and HOLI- When the “Follow Schedule”...
  • Page 10: Holiday

    Fig. 12 for outdoor temperature/indoor humidity relationship in Dehumidification Off — Dehumidification can be turned off auto humidification mode. completely. This can be done without changing existing set points. Humidification Off — The humidification function can be turned off completely. This does not require changing existing To Select Dehumidification —...
  • Page 11: Heat/Cool Set Points (Desired Temperature)

    There are two terminals, D1 and D2. When System wiring diagrams are provided for typical Carrier configured as a dehumidification output, the dry contact can equipment. See Fig. 13-27.
  • Page 12 COMMERCIAL THERMOSTAT CONNECTION BOARD / TB2† O/W2/B SRTN Humidi-MiZer™ FIOP a33-9174 LEGEND *Connection not required. †TB2 for 48/50HJ015-028 and 48/50TJ,TM016-028 units. FIOP — Factory-Installed Option Connection Board for all other units. — Fuse LTLO — Low Temperature Lockout Fig. 13 — Thermostat Wiring — 48/50HE003-006, 48/50HJ004-028, 48/50TF004-014, 48/50TJ016-028, 48/50TM004-028, 50HEQ003-006, and 50HJQ,TFQ004-012 Rooftop Units COMMERCIAL THERMOSTAT 48/50HJ,62AQ COBRA UNIT...
  • Page 13 COMMERCIAL THERMOSTAT TB1 / TB2† a33-9176 O/W2/B SRTN Humidi-MiZer™ FIOP *Connection not required. †TB1 for 48/50PG03-16 units and TB2 for 48/50PG,PM20-28 units and 48/50HG014-028 units. Fig. 15 — Thermostat Wiring — 48/50HG,PG,PM Rooftop Units COMMERCIAL THERMOSTAT COMMAND CENTER O/W2/B a33-9177 SRTN *Connection not required.
  • Page 14 COMMERCIAL THERMOSTAT O/W2/B a33-9178 ISOLATION RELAY SRTN *Connection not required. Fig. 17 — Thermostat Wiring — 50HJQ014,016 Heat Pump Units COMMERCIAL THERMOSTAT a33-9179 O/W2/B SRTN Fig. 18 — Thermostat Wiring — 50EJQ,EWQ024,028 Heat Pump Units...
  • Page 15 COMMERCIAL THERMOSTAT CONNECTION BOARD (TB) O/W2/B a33-9180 LLSV-1 X*/8 SRTN LLSV-2 38ARD012 38ARD014-024 LEGEND — Indoor Fan Contactor *Connection not required. LLSV — Liquid Line Solenoid Valve Fig. 19 — Thermostat Wiring — 38ARD Commercial Split System Units COMMERCIAL THERMOSTAT INDOOR UNIT O/W2/B a33-9181...
  • Page 16 COMMERCIAL THERMOSTAT COMPLETE C a33-9182 O/W2/B COMPLETE C FIRST COMPRESSOR SRTN SECOND COMPRESSOR Fig. 21 — Thermostat Wiring — 50HQL, KQE, KQL, PC, PEC, PS, PSW, PT, RHC, RHE, RHR, RHS, RTG, RVC, RVE, RVR, RVS, RWS, VQL Water Source Heat Pump Units with Complete C Controls COMMERCIAL THERMOSTAT DELUXE D a33-9183...
  • Page 17 COMMERCIAL THERMOSTAT TERMINAL BOARD Y/Y2 Y1/W2 a33-9184 O/W2 W/W1 O/W2/B DELUXE D SRTN Fig. 23 — Thermostat Wiring — 50PS, PT, RHS, RVS, VQL Water Source Heat Pump Units with Deluxe D Controls and Factory-Installed Reheat Option COMMERCIAL THERMOSTAT a33-9185 O/W2/B OAT SENSOR SRTN...
  • Page 18 COMMERCIAL THERMOSTAT STRN SENSOR 3 SENSOR 4 SENSOR 1 SENSOR 2 SPACE TEMPERATURE AVERAGING (4 SENSOR APPLICATION) COMMERCIAL THERMOSTAT STRN SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 SENSOR 5 SENSOR 6 SENSOR 1 SENSOR 1 SENSOR 1 SENSOR 7 SENSOR 8 SENSOR 9 SPACE TEMPERATURE AVERAGING (9 SENSOR APPLICATION)
  • Page 19 COMMERCIAL THERMOSTAT a33-9186 O/W2/B SRTN HUMIDIFIER DEHUMIDIFIER/ NOTES: 3. For humidifer control, 24-V is provided from the HUM terminal to 1. D1 and D2 can be used independently for equipment requiring a operate the equipment. dry contact. 4. For dehumidifer control, 24-V is applied from Rc to the 2.
  • Page 20 Copyright 2008 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53330010-01 Printed in U.S.A. Form 33CS-65SI Pg 20 8-08 Replaces: New...
  • Page 24: Thermostat Configuration Record

    Fan Selection During Unoccupied Periods Option 38 _____ Maximum Temporary Hold For Hours Copyright 2008 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53330010-01 Printed in U.S.A.

This manual is also suitable for:

Edge pro 33cs2pp2s-01

Table of Contents