Download Print this page

Panasonic Econavi XE9PKUA Quick Manual page 2

With intelligent eco sensors

Advertisement

Panasonic Adds a "NEW Air Conditioner" Line-up...
Setting Another Milestone in the History of Ductless Split.
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
No.1* High Energy Efficiency*
SEER
28.5
Breakthrough technology such as the inverter, enables the highest energy efficiency* in the
industry. Thanks to this exceptional performance, you can enjoy more comfort.
*CS/CU-XE9PKUA as of March 2013
Powerful Heating at Low Ambient
LOW
AMBIENT
Heating is still possible even if the temperature drops as low as 0˚F for reliable heating in the
OPERATION
middle of the harshest winter.
Inverter Technology
Panasonic's inverter technology provides optimum power control and extremely efficient
operation by changing the power supply frequency. The result is speedy, flexible operation using
less electricity.
Innovative Inverter Technology
The inverter constantly adjusts the compressor rotation speed to provide optimum
performance at all times. After reaching the set temperature, an inverter air conditioner
continues to operate with minimum power to avoid unnecessary electricity consumption.
Conventional non-inverter air conditioners can only operate at a constant speed, switching the
compressor ON and OFF to maintain the set temperature, which wastes electricity.
Advantages of Inverter Control
Comparing inverter and non-inverter air conditioners to cars.
Cooler
Adjusts the accelerator and
The accelerator can't be adjusted, so you spend a long
thus runs more economically.
time to get comfortable, then soon become uncomfortable.
Uncomfortable
Reaches the comfortable
Keeps the temperature
zone quickly.
comfortable all the time.
Comfortable
Setting Temperature
Uncomfortable
START
Inverter air conditioner
Runs at a fixed speed, so it takes
The room gets too cold,
Less Cool
longer to reach the comfort zone.
then too warm.
Non-inverter air conditioner
*Image of output power fluctuation
Wireless Remote
Controller
Room Freeze Protection
Specifications
Model No.
Unit Model No.
Performance & Electrical Ratings
Capacity
Cooling
Heating
Moisture Removal
High
Dry Air Flow
High
SEER
Cooling
EER
Cooling
HSPF
Heating
Power Supply
V, Phase, Hz
Running Amps
Cooling
Heating
Power Input
Cooling
Heating
Back-up Heater
Fuse or Circuit Breaker Capacity
Features
Controls
Low Ambient Control
Wireless Remote Controller
Wired Remote Controller (optional)
Fan Speeds
Inverter Compressor
Timer
Panasonic's Inverter Compressor can achieve high efficiency under
Air Deflection
Horizontal
high load conditions. With accumulated production of 200 Million
compressors, extremely high quality and reliability are proven.
Vertical
High Efficiency Motor
Air Filter
for wide operating voltage.
Refrigerant
Refrigerant Control
Operation Sound
In(Hi / Lo/ Q-Lo) dB-A
High Efficiency &
High Reliability Material
Optimum Shape
Outdoor(Hi)
for longer life span and to
Muffler
Refrigerant Piping
Type
withstand high pressure.
for quiet operation.
Discharge
Even Wider Output Power Range
Suction
Refrigerant Pipe Length
Minimum capacity
2,800
Btu/h
Elevation Difference*
Outdoor Above
Rated capacity
Outdoor Below
8,700
Btu/h
Maximum capacity
Dimensions & Weight
12,000
Btu/h
Height
Width
Depth
Net Weight
The graph shows CS-XE9PKUA's wide power
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
output range during cooling.
Outdoor Unit
CU-XE9PKUA
CU-XE12PKUA
XE9PKUA
XE12PKUA
Indoor Unit
Outdoor Unit
Indoor Unit
CS-XE9PKUA
CU-XE9PKUA
CS-XE12PKUA
Btu/h
8,700(2,800~12,000)
11,500(2,800~14,000)
Btu/h
12,000(3,000~18,000) (10,600 at 17˚F)
13,800(3,000~23,000) (13,500 at 17˚F)
Pints/H
1.3
2.3
CFM
405
530
28.5
25.5
16.1
14.35
12.5
12.0
230/208V, 1PH, 60Hz
230/208V, 1PH, 60Hz
A
2.5/2.8
3.8/4.2
A
4.0/4.5
5.2/5.8
W
540(150-850)
800(150-1,050)
W
860(150-1,650)
1,150(150-2,100)
kW
---
---
A
15
20
Microprocessor
Microprocessor
Equipped
Equipped
Included
Included
CZ-RD516C
CZ-RD516C
5 Speeds + Auto
5 Speeds + Auto
24hr Program
24hr Program
Manual
Manual
Automatic
Automatic
Washable + Anti Microbial Filter
Washable + Anti Microbial Filter
R-410A
R-410A
Electric Expansion Valve
Electric Expansion Valve
42 / 25 / 20
45 / 28 / 20
dB-A
48
49
Flare
Flare
in.
1/4"
1/4"
in.
3/8"
1/2"
Ft.
Max. 66
Max. 66
Ft.
Max. 49
Max. 49
Ft.
Max. 49
Max. 49
Indoor Unit
Outdoor Unit
Indoor Unit
in.
11-5/8"
27-3/8"
11-5/8"
in.
34-9/32"
34-15/32"
34-9/32"
in.
10-1/16"
12-5/8"
10-1/16"
Lbs.
24
97
24
Features
ECONAVI
ECONAVI features intelligent Human Activity
The air sweep function moves the louver up and
Sensor and new technologies that can detect
down in the air outlet, directing air in a "sweeping"
human activity and absence, and optimize air
motion around the room and providing comfort in
conditioner operation according to room
every corner.
conditions.
Cool/Dry
Mode
Room Freeze Protection
Room Freeze Protection mode helps prevent
plumbing damage due to sub-Freezing
Temperature. This mode automatically turns on
2 air guides to improve the air flow direction
the compressor for heat pump operation if the
room temperature falls to about 46°F.
Outdoor Unit
CU-XE12PKUA
*This function may not be performed if the unit is
not powered, or if the unit is unable to operate
such as in protection mode. Please consult with
the HVAC installers.
Louver can be manually set to the desired angle
Microprocessor-Controlled
by remote control.
Operation
Microprocessor control ensures that the
temperature and humidity levels in the room are
always comfortable.
After setting the temperature and functions
you desire, just relax. If the room temperature
is higher than the set temperature, cooling
Wireless Remote Control
operation begins. If the room temperature
is lower than the set temperature, heating
operation begins. During normal thermostat
Panasonic's infrared Remote Control with and
cycle operation, cooling and heating operations
easy-to-read LCD Display, gives the user the
automatically change in accordance with set
capability to adjust & set: temperature, sweep
temperature, time and room temperature
(louver control), fan speeds, timer and more, for
(Single Zone Heat Pump unit only).
complete automatic operation.
Dry Mode
The remote control unit allows you to set a
By coupling compressor and fan operation,
wide variety of timer-based operations. Such
intermittent operation can be precisely controlled
functions include automatic ON/OFF with a timer
according to room temperature, so that air is
setting, same time ON/OFF every day, ON timer,
efficiently dehumidified.
OFF timer and Combination timer.
5 Fan Speeds and Automatic
Outdoor Unit
Fan Operation
27-3/8"
34-15/32"
Convenient microprocessor control automatically
This feature allows the system to automatically
12-5/8"
adjusts fan speed to High, Medium or Low.
resume operation at its preset program, after
97
According to room temperature to maintain a
power is restored from a power failure when
comfortable airflow throughout the room.
the remote control is in the room.
Air Sweep Control
Hot Start Heating System
Right from the start, air is warm and comfortable.
The Hot Start Heating System prevents any cold
blasts at the beginning while the heat pump is
warming up (Heat pump unit only).
Electric Refrigerant Control
Valve
The circulation volume of the refrigerant is
Heat Mode
controlled by a pulse type electric control valve.
In order to attain optimum efficiency, when the
power is switched ON, the opening degree of the
electric control valve is controlled between 90
Cooling Mode
and 480 step.
Cool air doesn't reach
you directly so your
hands and feet don't
Quiet Mode
get cold.
2 air
guides
LOW, low fan speed for extra quiet operation.
Heating Mode
20dB
Leaves touch together
Warm feet and no direct
breeze on your face
mean even more
30dB
Whisper voice
comfort.
40dB
In a library
2 air
guides
50dB
In a office
60dB
Normal conversation
Louver Control
In a subway
80dB
Automatic Heating and
Self-Diagnosing Function
Cooling Changeover
Unit is equipped with Self-Diagnosing Function
with remote controller. This makes it easier to
diagnose malfunctions, reducing service labors.
24-hour Clock with ON/OFF
Program Timer
Blue Fin Condenser
Condensers can take a beating from exposure to
salty air, rain and other corrosive factors.
Panasonic has extended the life of its
condensers with an original anti-rust coating.
Automatic Restart Function
Special Coating Layer
after Power Failure
(Fin Cross-section)
Water Air Salt content
Base material
Corrosion-resistant layer

Advertisement

loading

This manual is also suitable for:

Econavi xe12pkua