Download Print this page

Kenmore 415.16115 Assembly Instructions/Use And Care Manual page 24

Liquid propane gas grill

Advertisement

Troubleshooting
EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
, Damaged hose.
, Turnoff gasat LP tank.If hoseis cut or cracked,replace
Gasleakingfrom
cracked/cut/burned
valve/hose/regulator. See LPTankLeakTestandConnecting
hose.
Regulator T oTheLPTank.
Gasleakingfrom LP
, Mechanical failuredue to rustingor
, Turnoff LP tankvalve.
tank.
mishandling.
Gasleakingfrom LP
, Failureof tankvalvefrom mishandling or
, Turnoff LPtank valve.ReturnLP tankto gassupplier.
tank valve,
mechanical failure.
Gasleakingbetween
, Improper installation, connection not
, Turnoff LP tankvalve.Removeregulator f rom cylinder and visually
LPtankand regulator
tight,failureof rubberseal.
inspectrubbersealfor damage. S ee LPTankLeakTestand
connection.
Connecting Regulator ToThe LPTank.
Firecomingthrough
, Firein burnertubesectionof burnerdue
, Turnoff controlknobsand LP tankvalve.Leavelid opento allow
controlpanel,
to partialblockage,
flamesto die down.Afterfire isout andgrill is cold.removeburner
andinspectfor spidernestsor rust.See NaturalHazardandCleaning
TheBurner Assembly pages.
DO
e :
,
, Toomuchgreasebuildupin burnerarea.
Greasefire or
continuous excessive
flamesabovecooking
surface.
Burner(s) w ill not light
usingignitor.
GASISSUES:
, Trying to lightwrongburner.
, Burnernotengaged with controlvalve.
, Obstruction in burner.
Continued on next
page.
, Nogasflow.
, Vapor lock at coupling nut to LP tank.
, Couplingnutand LPtankvalve notfully
connected.
ELECTRICAL ISSUES:
, Electrode crackedor broken; " sparksat
crack."
, Electrode tip notin properposition.
, Wireand/orelectrodecovered with
cookingresidue.
, Wiresare looseor disconnected.
, Wiresare shorting (sparking) between
ignitorand electrode.
, Turnoff LPtank valve.Leavelid opentoallowflamesto die down.
After cooling, c leanfoodparticlesand excessgreasefrom inside
fireboxarea.greasecup/pan/tray, and othersurfaces.
, See instructions on control panel and section in the Use and Care.
, Make sure valves are positioned inside of burner tubes.
, Ensure burner tubes are not obstructed with spider webs or other
matter. See cleaning section of Use and Care.
, Make sure LP tank is not empty. If LP tank is not empty, refer to
"Sudden drop in gas flow."
, Turn off knobs and disconnect coupling nut from LP tank. Reconnect
and retry.
, Turn the coupling nut approximately one-half to three-quarters
additional turn until solid stop. Tighten by hand only - do not use tools.
, Replace electrode.
, Tipofelectrodeshouldbe pointing towardportholein burner. T he
distance shouldbe 1/8"to 3/16".Adjustif necessary.
, Cleanwire and/orelectrode with rubbing alcoholand cleanswab.
, Reconnect w iresor replaceelectrode/wire assembly.
, Replace ignitorwire.
24 •464321607and 464321407

Advertisement

loading

This manual is also suitable for:

640.122390.115