Fuel Conversion Instructions - Kenmore Economizer 5 153.333830 Owner's Manual

Gas water heater
Table of Contents

Advertisement

Installation
Instructions (cont'd)
Step 20. At arm's length away,set the thermostat to desired set-
ting. The mark _
HOT indicative of approx. 120°F is
LP,,referred
starting pint. If hotter water is desired see the
Temperature Regulation section in this manual.
"A" (
KNOB
AWARNING
Hotter
water
increases
the risk of scald inlury.
Before
changing
temperature
setting
see the
"Temperature
Regulation" section in this manual.
GAS
UNE
Step21.
Replace the outer door ifnot replaced in step 17.
Step 22. Remove adhesive label found in conversion kit and
place next to the model rating plate. Mark label indi-
cating for which type gas the water heater is now
equipped.
"Fuel"
Conversion
Instructions
From Propane
(L.P.) Gas To Natural
Gas
TEMPERATURE
it- PLASTIC CAP
ADJ.DIAL
,,
"_-- o _
_R NATURAL
[ Figure
I ]
IN FOP,PROPANE (LR)
AWARNING
This water heater has been factory equipped to operate
with the type gasindicated in the "EQUIPPED FOR" area
of the model rating plate located near the gas control
valve. The indicated gas may he either Natural
or
Propane (LR). By following the conversioninstructionsin
this manual or the instructionsnear the gascontrol valve,
the water heater must he converted if it is to he used
with the opposite gas. DO NOT USE THIS WATER
HEATER WITH ANY GAS OTHER THAN THE ONE
LISTED ON THE MODEL RATING PLATE. Failure to use
the correct gas can cause problems which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. If you have any questions or doubts consult
your gas supplier or gascompany.
To convert from Propane (L.P.) gas to Natural gas, follow the
"Fuel" Conversion Iristructions
From the =Natural Gas to
Propane (LP.) Gas" section except in Step 5, use orifice "E",
marked "NAT.". In Step 6 use pilot orifice "G", brass color and
in Step 8 turn control screw "B _"in Figure 1 clockwise (f-"%)
to stop. Screw must be in "OUT" position for Natural gas.
See =Instruction
Label" for orifice sizes.
Maximum Supply Pressure:
14"W.C. For Nat. Gas.
14" W.C. for Propane (L.E) Gas
Minimum Supply Pressure
5" W.C. for Nat. Gas.
11" W.C. For Propane (L.E) Gas
NOT "H"
THERHOCOUPLE ][
L_
LL PILOT TUBING
IF,guru2} N,FOLO
BURNER
,
PILOT TUBING'_
_
I Figure 41
"F"
17