Water Piping - Kenmore Economizer 5 153.333830 Owner's Manual

Gas water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Water Piping (cont'd)
• Look at the top cover of the water heater. The water outlet is
marked hot. Put two or three turns of teflon tape around the
threaded end of the threaded-to-sweat coupling and around
both ends of the ¾ threaded nipple. Using flexible connec-
tors, connect the hot water pipe to the hot water outlet of the
water heater.
• Look at the lower fight side of the water heater. The cold
water inlet is marked cold. Put two or three turns of teflon
tape around the threaded end of the threaded-to-sweat cou-
pling and around both ends of the _A" threaded nipple. Using
flexible connectors, connect the cold water pipe to the cold
water inlet of the water heater.
WATER
PIPING
PRESSURE
TEST
This section is only for the mobile home manufacturerinstalling
the water heater when the installation is to comply with H.U.D.
Standards.
When testing the water ways, H.U.D. Standards state:
"Water distribution system. All water piping in the water dis-
tribution system shall be subjected to a pressure test. The test
shaft be made by subjecting the system to air or water at 100
psi for 15 minutes without loss of ptessure. When air pres-
sure is used, the water heater shall not be connected dur-
hag the test."
NOTE: This water heater
is insulated
to minimize
heat loss
ficom the tank. Further reduction
in heat loss can be accom-
plished
by insulating the hot water lines from the water
_ttero
INSTALLATION
COMPLETED
USING
SEARS INSTALLATION
KIT
HO3" OUTL_t_
TO HOUSE/
THREADED
TO
SWEAT
COUPLING
CONNECTOR
PRESSURE
RELIEF VALVE
THREADED
TO
SWEAT COUPLING
FLEXIBLE WATER
shutoff
COLD INLET
WATER
LINE
314" THREADED_
COUPLINGS
&WARNING
If the water piping system is to be air pressure test.
ed, the water
heater must be disconnected from
the water piping system. Failure to disconnect the
water
heater
during air pressure testing
of the
water piping system could result IN DEATH,
SERI-
OUS BODILY INJURY, OR PROPERTY DAMAGE.
HOT OUTLET
WHEN
AIR TESTING,
REMOVE THE WATER
LINES FROM THE
WATER HEATER
COLD INLET
(Do not cap or plug.
Must terminate
beneath
Mobile Home)