Garmin GDU 370 Installation Manual page 153

Garmin gps receiver installation manual
Hide thumbs Also See for GDU 370:
Table of Contents

Advertisement

3. Connect a Flat Braid (item 4) to the shield exposed through the window of the prepared cable
assembly (item 2) from step 2. The Flat Braid should go out the front of the termination towards
the connector. It is not permitted to exit the rear of the termination and loop back towards the
connector (Figure B-6). Make this connection using an approved shield termination technique.
FAA AC 43.13-1B Chapter 11, Section 8 (Wiring Installation Inspection Requirements)
may be a helpful reference for termination techniques.
Preferred Method:
Slide a solder sleeve (item 3) onto the prepared cable assembly (item 2) and connect the Flat Braid
(item 4) to the shield using a heat gun approved for use with solder sleeves. It may prove beneficial
to use a solder sleeve with a pre-installed Flat Braid versus having to cut a length of Flat Braid to be
used. The chosen size of solder sleeve must accommodate both the number of conductors present in
the cable and the Flat Braid (item 4) to be attached.
Solder Sleeves with pre-installed Flat Braid
A preferred solder sleeve would be the Raychem S03 Series with the thermochromic temperature
indicator (S03-02-R-9035-100, S03-03-R-9035-100, S03-04-R-9035-100). These solder sleeves come
with a pre-installed braid and effectively take the place of items 3 and 4. For detailed instructions on
product use, reference Raychem installation procedure RCPS 100-70.
Raychem recommended heating tools:
HL1802E
AA-400 Super Heater
CV-1981
MiniRay
IR-1759
Individual solder sleeves and Flat Braid
Solder Sleeves:
Reference the following MIL-Specs for solder sleeves.
(M83519/1-1, M83519/1-2, M83519/1-3, M83519/1-4, M83519/1-5)
Flat Braid:
If the preferred Raychem sleeves are not being used, the individual flat braid selected should
conform to ASTMB33 for tinned copper and be made up of 36 AWG strands to form an
approximately 19-20 AWG equivalent flat braid. A circular mil area range of 1000 to 1300 is
required. The number of individual strands in each braid bundle is not specified. (e.g.
QQB575F36T062)
Flat Braid as opposed to insulated wire is specified in order to allow continuing air
worthiness by allowing for visual inspection of the conductor.
G3X Installation Manual – Appendix B
190-01115-01
NOTE
NOTE
Page B-9
Revision A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdu 375Gmu 44Gsu 73Gtp 59G3xGdu 37x

Table of Contents