B-18 Daisy Chain Shield Termination - Garmin GDU 370 Installation Manual

Garmin gps receiver installation manual
Hide thumbs Also See for GDU 370:
Table of Contents

Advertisement

B.4.3 Daisy Chain Shield Termination Technique – Method A
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal (Figure
B-18). All other restrictions and instructions for the shield termination technique set forth for Method
A.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure B-18. Daisy Chain Shield Termination