Water - Manual Fill; Water - Auto Fill; Programming The Buttons 1-5 - Hatco STM-4G Series Installation & Operating Manual

Table of Contents

Advertisement

WATER - MANUAL FILL

CAUTION
Do not fill with water above or beyond the
maximum water line (1 liter) on the water tank or
damage may occur to the unit.
NOTICE
To assure proper operation and to prevent lime
and scale buildup inside the unit, use distilled
water or water that has been treated to prevent
scale build-up.
1. Remove and fill water tank to an appropriate
level (1 liter) between the minimum and
maximum water lines located on the water tank.
Use both hands when carrying a full water tank.
(See Figure 8.)
2. Completely dry the outer surface of the water
tank and place water tank fully inside the cavity
until it connects. Take care not to let any water
spill out.
WARNING
To avoid electrical shock or personal injury, DO
NOT insert into the unit a water tank that is wet
on the outside.
3. Wipe away any water that may be on the floating
disc. (See Figure 5.)
WATER - AUTO FILL (RECOMMENDED
FOR COMMERCIAL USE)
NOTE: Auto boiler drain occurs when the power is
switched off. The drain valve will be turned on for 1
minute to drain all the water/descaling agent in the
boiler to the drip pan and drain hose. There may be
some "noise" from the drain valve when the boiler
runs out of water and is empty.
1. Make sure water line is properly connected to the
water supply.
NOTE: A hose is recommended to be connected to
the drip pan for drainage.
2. Open the door, press and hold the Start/Stop
button for two seconds until AUTO appears in the
display. (See Figure 8.) Release the Start/Stop
button and close the door.
NOTE: When the unit is turned on, it will default to
Manual Fill mode. Repeat step 2 to switch to Auto
Fill mode. Once set in Auto mode, the unit will stay
in Auto mode unless it is unplugged from the power
source.
Maximum
Water Level
Minimum Water Level
Figure 8. Water Level
PROGRAMMING THE BUTTONS 1 - 5
The Steamer comes with the following factory
presets:
Button
Temperature
1
2
3
4
5
To reprogram a menu button:
1. Press and hold the I/O Power button for two
seconds to turn the Electric Steamer on. Timer
display will be at 0:00 and the Temperature
display will show the current temperature inside
the cabinet when unit is first turned on.
2. Press the desired Program Menu button (1-5).
3. Press the (+) or (-) Timer buttons until the desired
time is shown on the Timer Display. Pressing and
holding the (+) or (-) Timer button will rapidly
increase or decrease the set time.
4. Press the (+) or (-) Temperature buttons until the
desired
temperature
Temperature Display. Pressing and holding the
(+) or (-) Temperature button will rapidly increase
or decrease the set temperature.
5. Press the Program button until a beep is heard,
then release the button. The new program is now
saved.
6. Repeat steps 2 - 5 for the other 4 buttons.
NOTE:
See
charts
recommended cook times and temperatures.
9
OPERATION
Minutes
95°C
5
100°C
6
100°C
7
100°C
8
100°C
9
is
shown
on
on
pages
12-14
Form No. STMSM-1007
the
for

Advertisement

Table of Contents
loading

Table of Contents