Technical Data

This cooker is category II
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB
Gas
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Minimum space above hotplate
Connections
Gas:
Rp 1/2 at rear right-hand side
Ratings
Hotplate
Right hand Wok burner
Large Burners
Medium Burners
Small Burner
Gas burner inputs based on Gross Calorifi c Value
Ovens
Energy effi ciency class :
on a scale of A (more effi cient) to G (less effi cient)
Energy consumption based on standard load
Usable volume (litres)
Size
Time to cook standard load
Baking area
Grill
Maximum total electrical load at 230V 8.8 kW (approximate total including oven lights, oven fan etc.)
2H3+
20mbar
29mbar
37mbar
Overall height
minimum 896mm
Overall width
900mm See 'Positioning of Cooker'
Overall depth
648mm
Space for fixing
See 'Positioning of Cooker'
650mm
Natural Gas
Injector
internal 80
3.65kW
external 129
3.0kW
134
1.7kW
109
1.0kW
75
2.3kW
Electric
220 - 240V 50Hz
maximum 925mm
Electric
220 - 240V 50Hz
L.P. Gas
3.5kW (255g/h)
3.0kW (218g/h) 87
1.7kW (124g/h) 68
1.0kW (73g/h)
Multifunction
0.90kWh
Medium
41 minutes
1400cm
37
Injector
internal 54
external 77
51
Tall Oven
B
0.95kWh
62
Medium
49 minutes
2
790cm
B
67
2