Dimensions & Specifications; Dimensions & Specifications - Garland 200 Service Manual

Full size "gas" convection ovens with 200, 410, 450, 455, 470, 475 series controllers
Table of Contents

Advertisement

DIMENSIONS & SPECIFICATIONS
Int . Dimensions :In (mm)
Single-Deck
Models
Standard Depth 29 (736) 24 (610) 24 (610) 38 (965) 57-1/2 (1461)
Deep Depth
29 (736) 24 (610) 28 (711) 38 (965) 57-1/2 (1461)
Int . Dimensions: In (mm)
Double-Deck
Models
Standard Depth
29 (736) 24 (610) 24 (610) 38 (965) 70-1/2 (1791)
Deep Depth
29 (736) 24 (610) 28 (711) 38 (965) 70-1/2 (1791)
*Height with or without standard casters. Height with low profile casters (double deck) is 68-1/2" (1740mm).
Models
Single Deck
Double Deck
3/4" N.PT.
GAS INLET
7-3/4"
[197mm]
3/4"
[19mm]
FLUE: 2-3/8" x 5"
[60mm x 127mm]
D
Includes
(
fan motor)
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
H
25-3/8"
[645mm]
SINGLE DECK
FR ONT VIEW
Gas Input ratings shown here are for installations up to 2,000-ft. (610m) above sea level. Specify altitudes over 2,000 ft.
Commercial cooking equipment requires an adequate ventilation system. For additional information, refer to the National Fire
Protection Association's standard NFPA96, "Vapor Removal from Cooking Equipment." (NOTE: For North America only)
Please specify gas type when ordering.
Part # MCOSM06 Rev 1 (11/03/08)
W
H
D
W
H
D
Input Ratings, Nat & Pro
BTU/hr
kW Equiv .
60,000
17. 6
120,000
35.2
2"
[51mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
TOP VIEW
38"
[965mm]
3/4" REAR
GAS INLET
54-9/16"
[1386mm]
34"
[864mm]
Ext . Dimensions: In (mm)
W
H *
41-1/4(1048)
44-1/2(1130)
Ext . Dimensions: In (mm)
W
H *
41-1/4(1048)
44-1/2(1130)
Electrical Specifications
Gas Inlet
120V/1Ph .
(1 )@ 3/4" NPT
(1)@9.4A
(1 )@1" NPT
(2)@9.4A
1-1/4"
[32mm]
32-1/8"
[816mm]
H
32-1/8"
[816mm]
6-1/4"
[159mm]
Installation Notes:
Combustible Wall Clearances:
Sides: 1" (25mm)
Back: 3" (76mm)
Entry Clearance:
Crated: 47" (1194mm)
Uncrated: 32-1/2" (826mm)
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V 3/4 HP, 2-speed motor; 1140 and 1725 rpm 60Hz
3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.
5. Garland recommends a separate 15 AMP circuit for each 120V unit.
Ship Wt
Ship Dim .
D
Lbs/kg
Cubic Ft .
600/273
64
600/273
64
Ship Wt .
Ship Dim .
D
2@Lbs/kg
Cubic Ft .
1150/523
128
1150/523
128
240V/1Ph .
(1)@ 5.2A
(2)@ 5.2A
1" REAR
GAS INLET
32-1/8"
[816mm]
32-1/8"
[816mm]
35-7/16"
[900mm]
14-3/4"
[375mm]
DOUBLE DECK
FR ONT VIEW
Operating Pressure:
Natural: 4.5" WC (11 mbar)
Propane: 10" WC (25 mbar)
Max 13.8" WC @ 70°F (21°C)
NOTE: Data applies only to
North America
Page 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mco gs seriesMco gd series

Table of Contents