In Water Mode,
Is the voltage between
pin4 and pin11 of CON3 in
main PCB like as below,
while pushing the level
switch?
Output voltage of machine room water valve
Test Point
pin4 to pin11
Yes
First Water- valve
Is the resistance value
between (1) and (2) of the
First-water valve like as
below?
Checking resistance of First-valve
Test Point
(1) to (2)
Yes
Replace
No
Main PCB
Main PCB
CON3
Pin11 GN
Pin4 BL
Result
115 V
Replace
No
First
Water-valve
(1)
(2)
Machine room
Result
360 ~420
Second Water- valve
Is the resistance value of
Second-water valve like as
below?
Dispenser
Checking resistance of Second-valve
Test Point
(1) to (2)
Yes
Is the condition of
the micro switch like as
below?
(1)
(2)
Status
Normal
Push the Lever
Yes
After plug in,
explain to the customer!
- 35 -
Replace
No
Second
Water-valve
(1)
(2)
In door
Ice Maker
Result
360 ~ 420
Replace
No
Micro
Switch
Tester
Infinity
0