  • Page 1 ES3628EA 24 10/100 Ports + 4G L2/L3/L4 Intelligent Switch Installation Guide www.edge-core.com...
  • Page 3 Installation Guide 24 10/100 Ports + 4G L2/L3/L4 Intelligent Switch Layer 3 Standalone Switch with 24 100BASE-TX (RJ-45) Ports, 2 1000BASE-T (RJ-45) Ports, and 2 SFP Slots...
  • Page 4 ES3628EA E112007-DT-R01 150200064200A...
  • Page 5: Japan Vcci Class A

    Compliances and Safety Warnings FCC - Class A This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
  • Page 6 CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC.
  • Page 7: Safety Compliance

    Safety Compliance Warning: Fiber Optic Port Safety When using a fiber optic port, never look at the transmit laser while it is CLASS I powered on. Also, never look directly at the fiber TX port and fiber cable LASER DEVICE ends when they are powered on.
  • Page 8 Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following: Power Cord Set U.S.A. and Canada The cord set must be UL-approved and CSA certified. The minimum specifications for the flexible cord are: - No.
  • Page 9 France et Pérou uniquement: Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec raccordement direct à...
  • Page 10: Warnings And Cautionary Messages

    Stromkabel . Dies muss von dem Land, in dem es benutzt wird geprüft werden: Schweiz Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalt- Europe Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung) sein und die Aufschrift <HAR> oder <BASEC> tragen. Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”). Warnings and Cautionary Messages Warning: This product does not contain any serviceable user parts.
  • Page 11: Related Publications

    All printed documentation for this product uses biodegradable paper that originates from sustained and managed forests. The inks used in the printing process are non-toxic. Purpose This guide details the hardware features of the ES3628EA switch, including its physical and performance-related characteristics, and how to install the switch. Related Publications...
  • Page 12 viii...
  • Page 13: Table Of Contents

    Contents Chapter 1: Introduction Overview Switch Architecture Network Management Options Description of Hardware 100BASE-TX and 1000BASE-T Ports SFP Slots Status LEDs Optional Redundant Power Supply Power Supply Receptacles Features and Benefits Connectivity Expandability Performance Management Chapter 2: Network Planning Introduction to Switching Application Examples Collapsed Backbone Network Aggregation Plan...
  • Page 14 Contents Chapter 4: Making Network Connections Connecting Network Devices Twisted-Pair Devices Cabling Guidelines Connecting to PCs, Servers, Hubs and Switches Network Wiring Connections Fiber Optic SFP Devices Connectivity Rules 1000BASE-T Cable Requirements 1000 Mbps Gigabit Ethernet Collision Domain 100 Mbps Fast Ethernet Collision Domain 10 Mbps Ethernet Collision Domain Cable Labeling and Connection Records Appendix A: Troubleshooting...
  • Page 15 Tables Table 1-1 Port Status LEDs Table 1-2 System Status LEDs Table 3-1 Serial Cable Wiring Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Length Table 4-3 Maximum 1000BASE-LX Gigabit Ethernet Cable Length Table 4-4 Maximum 1000BASE-LH Gigabit Ethernet Cable Length Table 4-5...
  • Page 16 Figures Figure 1-1 Front and Rear Panels Figure 1-2 Port LEDs Figure 1-3 System LEDs Figure 1-4 Power Supply Receptacles Figure 2-1 Collapsed Backbone Figure 2-2 Network Aggregation Plan Figure 2-3 Remote Connection with Fiber Cable Figure 2-4 Making VLAN Connections Figure 2-5 IP Routing for Unicast Traffic Figure 3-1...
  • Page 17: Chapter 1: Introduction

    Chapter 1: Introduction Overview The ES3628EA 24 10/100 Ports + 4G L2/L3/L4 Intelligent Switch has 24 100BASE-TX ports, 2 1000BASE-T ports, and 2 SFP transceiver slots. There is also an SNMP-based management agent embedded on the main board. This agent supports both in-band and out-of-band access for managing the switch.
  • Page 18: Network Management Options

    Description of Hardware 100BASE-TX and 1000BASE-T Ports The ES3628EA contains 24 100BASE-TX RJ-45 ports that operate at 10/100 Mbps, half or full duplex, and 2 1000BASE-T RJ-45 ports that operate at 1000 Mbps, full duplex. Because all RJ-45 ports on this switch support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
  • Page 19: Status Leds

    Description of Hardware Status LEDs The ES3628EA includes a display panel for key system and port indications that simplify installation and network troubleshooting. The LEDs, which are located on the front panel for easy viewing, are shown below and described in the following table.
  • Page 20: Optional Redundant Power Supply

    Introduction System Indicators Figure 1-3 System LEDs Table 1-2 System Status LEDs Condition Status Power On Green Internal power is operating normally. On Amber Internal Power supply fault. Power off or failure. Diag Flashing Green System self-diagnostic test in progress. On Green System self-diagnostic test successfully completed.
  • Page 21: Features And Benefits

    Features and Benefits Features and Benefits Connectivity • 24 100BASE-TX ports for 10 or 100 Mbps Ethernet connections. Auto-negotiation enables each RJ-45 port to automatically select the optimum communication mode (half or full duplex) if this feature is supported by the attached device; otherwise the port can be configured manually.
  • Page 22 Introduction...
  • Page 23: Chapter 2: Network Planning

    Chapter 2: Network Planning Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today’s networking technology.
  • Page 24: Application Examples

    Network Planning Application Examples The ES3628EA switch is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described in the following pages. Collapsed Backbone The ES3628EA is an excellent choice for mixed Ethernet, Fast Ethernet, and Gigabit Ethernet installations where significant growth is expected in the near future.
  • Page 25: Network Aggregation Plan

    Application Examples Network Aggregation Plan With 28 parallel bridging ports (i.e., 28 distinct collision domains), the ES3628EA can collapse a complex network down into a single efficient bridged node, increasing overall bandwidth and throughput. In the figure below, the 100BASE-TX ports on the switch are providing 100 Mbps full-duplex connections for up to 24 local segments through stackable switches.
  • Page 26: Remote Connections With Fiber Cable

    1000BASE-LX SFP can be used to connect to other buildings in a campus setting, and a 1000BASE-LH SFP transceiver can be used for a long-haul connection to a remote site. The figure below illustrates an ES3628EA switch connecting multiple segments with fiber cable. ES3628EA...
  • Page 27: Making Vlan Connections

    At Layer 3, VLANs are used to create an IP interface, where one or more ports are assigned to the same IP segment. Traffic is automatically routed between different IP segments on the same switch, without any need to configure routing protocols. R&D ES3628EA VLAN 1 Console Power...
  • Page 28: Using Layer 3 Routing

    VLANs can significantly enhance network performance and security. However, if you use conventional routers to interconnect VLANs, you can lose most of your performance advantage. The ES3628EA provides wire-speed routing, which allows you to eliminate your conventional IP routers, except for a router to handle non-IP protocols and a gateway router linked to the WAN.
  • Page 29: Application Notes

    Application Notes Application Notes Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem.
  • Page 30 Network Planning...
  • Page 31: Chapter 3: Installing The Switch

    Chapter 3: Installing the Switch Selecting a Site Switches can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. • The site should: • be at the center of all the devices you want to link and near a power outlet. •...
  • Page 32: Equipment Checklist

    Then, before beginning the installation, be sure you have all other necessary installation equipment. Package Contents • ES3628EA 24 10/100 Ports + 4G L2/L3/L4 Intelligent Switch • Four adhesive foot pads • Bracket Mounting Kit containing two brackets and four screws for attaching the brackets to the switch •...
  • Page 33: Mounting

    Mounting Mounting A switch unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: •...
  • Page 34: Figure 3-3 Installing The Switch In A Rack

    Installing the Switch Mount the device in the rack, using four rack-mounting screws (not provided). Figure 3-3 Installing the Switch in a Rack If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter. If installing multiple switches, mount them in the rack, one below the other, in any order.
  • Page 35: Desktop Or Shelf Mounting

    Mounting Wenn Sie nur einen Switch installieren, dann springen Sie bitte über zu "Verbinden mit einer Stromquelle" auf Seite 3-7 am Ende dieses Kapitels. Wenn Sie mehrere Switches installieren möchten, dann montieren Sie sie untereinander in einer beliebigen Reihenfolge. Desktop or Shelf Mounting Attach the four adhesive feet to the bottom of the first switch.
  • Page 36: Installing An Optional Sfp Transceiver

    Installing the Switch If installing a single switch only, go to “Connecting to a Power Source” at the end of this chapter. If installing multiple switches, attach four adhesive feet to each one. Place each device squarely on top of the one below, in any order. Installing an Optional SFP Transceiver Figure 3-5 Inserting an SFP Transceiver into a Slot This switch supports 100BASE-FX, 1000BASE-T, 1000BASE-SX, 1000BASE-LX,...
  • Page 37: Connecting To A Power Source

    Connecting to a Power Source Connecting to a Power Source To connect a device to a power source: Insert the power cable plug directly into the receptacle located at the back of the device. Figure 3-6 Power Receptacle Plug the other end of the cable into a grounded, 3-pin socket. Note: For International use, you may need to change the AC line cord.
  • Page 38: Connecting To The Console Port

    Installing the Switch Connecting to the Console Port The DB-9 serial port on the switch’s front panel is used to connect to the switch for out-of-band console configuration. The on-board configuration program can be accessed from a terminal or a PC running a terminal emulation program. The pin assignments used to connect to the serial port are provided in the following table.
  • Page 39: Chapter 4: Making Network Connections

    Chapter 4: Making Network Connections Connecting Network Devices The ES3628EA 24 10/100 Ports + 4G L2/L3/L4 Intelligent Switch is designed to interconnect multiple segments (or collision domains). It can be connected to network cards in PCs and servers, as well as to hubs, switches or routers. It may also be connected to other devices using optional SFP transceivers.
  • Page 40: Network Wiring Connections

    Label the cables to simplify future troubleshooting. See “Cable Labeling and Connection Records” on page 4-5. Equipment Rack (side view) Network Switch ES3628EA w it ch 10 /1 0 0 6 7 2 4 L 3 Console Console Power...
  • Page 41: Fiber Optic Sfp Devices

    Fiber Optic SFP Devices Fiber Optic SFP Devices An optional SFP transceiver (100BASE-FX, 1000BASE-SX, 1000BASE-LX or 1000BASE-LH) can be used for a backbone connection between switches, or for connecting to a high-speed server. Each multimode fiber optic port requires 50/125 or 62.5/125 micron multimode fiber optic cabling with an LC connector at both ends.
  • Page 42: Connectivity Rules

    Making Network Connections As a connection is made, check the Link LED on the switch corresponding to the port to be sure that the connection is valid. 100BASE-FX fiber optic ports operate a 100 Mbps full duplex. 1000BASE-SX, 1000BASE-LX and 1000BASE-LH fiber optic ports operate at 1 Gbps full duplex. All of these SFP modules also support auto-negotiation of flow control.
  • Page 43: 100 Mbps Fast Ethernet Collision Domain

    Cable Labeling and Connection Records Table 4-3 Maximum 1000BASE-LX Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9/125 micron 2 m - 5 km (7 ft - 3.2 miles) LC single-mode fiber Table 4-4 Maximum 1000BASE-LH Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length...
  • Page 44 Making Network Connections • Note the length of each cable and the maximum cable length supported by the switch ports. • For ease of understanding, use a location-based key when assigning prefixes to your cable labeling. • Use sequential numbers for cables that originate from the same equipment. •...
  • Page 45: Appendix A: Troubleshooting

    Appendix A: Troubleshooting Diagnosing Switch Indicators Table A-1 Troubleshooting Chart Symptom Action Power LED is Off • Power supply is disconnected. • Check connections between the switch, the power cord, and the wall outlet. • Contact your dealer for assistance. Power LED is Amber •...
  • Page 46: Installation

    Troubleshooting Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.
  • Page 47: Appendix B: Cables

    Appendix B: Cables Twisted-Pair Cable and Pin Assignments For 10BASE-T and 100BASE-TX connections, a twisted-pair cable must have two pairs of wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be green and the other, green with white stripes.
  • Page 48: Straight-Through Wiring

    Cables Table B-1 10/100BASE-TX MDI and MDI-X Port Pinouts MDI Signal Name MDI-X Signal Name Transmit Data plus (TD+) Receive Data plus (RD+) Transmit Data minus (TD-) Receive Data minus (RD-) Receive Data plus (RD+) Transmit Data plus (TD+) Receive Data minus (RD-) Transmit Data minus (TD-) 4,5,7,8 Not used...
  • Page 49: 1000Base-T Pin Assignments

    Twisted-Pair Cable and Pin Assignments 10/100BASE-TX Crossover Cable White/Orange Stripe Orange White/Green Stripe End A End B Blue White/Blue Stripe Green White/Brown Stripe Brown Figure B-3 Crossover Wiring 1000BASE-T Pin Assignments All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
  • Page 50: 1000Base-T Cable Requirements

    Cables 1000BASE-T Cable Requirements All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, Category 5e (enhanced Category 5) or Category 6 cable should be used.
  • Page 51: Appendix C: Specifications

    Appendix C: Specifications Physical Characteristics Ports 24 100BASE-TX RJ-45 ports, 2 1000BASE-T RJ-45 ports, 2 SFP slots Network Interface Ports 1-24: RJ-45 connector, auto MDI/X 10BASE-T: RJ-45 (100-ohm, UTP cable; Category 3 or better) 100BASE-TX: RJ-45 (100-ohm, UTP cable; Category 5 or better) Ports 25-26: RJ-45 connector, auto MDI/X 10BASE-T: RJ-45 (100-ohm, UTP cable;...
  • Page 52: Switch Features

    Specifications Humidity Operating: 5% to 95% (non-condensing) AC Input 100 to 240 V, 50-60 Hz, 0.8A Power Supply Internal, auto-ranging transformer: 90 to 240 VAC, 47 to 63 Hz External, supports connection for 14-pin redundant power supply Power Consumption 28.44 Watts maximum Maximum Current 0.56 A @110 VAC 0.32 A @ 240 VAC...
  • Page 53: Standards

    Standards Standards IEEE 802.1D (Bridging) IEEE 802.3-2002 Ethernet, Fast Ethernet, Gigabit Ethernet Full-duplex flow control Link Aggregation Control Protocol ISO/IEC 8802-3 Compliances Emissions FCC Class A Industry Canada Class A EN 55022 (CISPR 22) Class A EN 61000-3-2/3 VCCI Class A C-Tick - AS/NZS 3548 (1995) Class A Immunity EN 61000-4-2/3/4/5/6/8/11...
  • Page 54 Specifications...
  • Page 55: Glossary

    Glossary 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable. 100BASE-FX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two strands of 50/125 or 62.5/125 micron core fiber cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 UTP cable.
  • Page 56 Glossary Collision Domain Single CSMA/CD LAN segment. CSMA/CD CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication method employed by Ethernet, Fast Ethernet, or Gigabit Ethernet. End Station A workstation, server, or other device that does not forward traffic. Ethernet A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable.
  • Page 57 Glossary IEEE 802.3x Defines Ethernet frame start/stop requests and timers used for flow control on full-duplex links. IEEE 802.3z Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet. LAN Segment Separate LAN or collision domain. Light emitting diode used for monitoring a device or network condition. Local Area Network (LAN) A group of interconnected computer and support devices.
  • Page 58 Glossary Transmission Control Protocol/Internet Protocol (TCP/IP) Protocol suite that includes TCP as the primary transport protocol, and IP as the network layer protocol. Unshielded twisted-pair cable. Virtual LAN (VLAN) A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network.
  • Page 59: Index

    Index cooling problems A-1 Numerics cord sets, international 3-7 10 Mbps connectivity rules 4-5 100 Mbps connectivity rules 4-5 1000 Mbps connectivity rules 4-4 DC input 1-4 1000BASE-T desktop mounting 3-5 pin assignments B-3 device connections 4-1 ports 1-2 100BASE-TX pin assignments B-1 electrical interference, avoiding 3-1 ports 1-2...
  • Page 60 Index location requirements 3-1 routing applications 2-7 optional redundant power supply 1-4 rubber foot pads, attaching 3-5 management agent 1-2 features 1-5, C-2, C-3 out-of-band 1-2 screws for rack mounting 3-2 SNMP 1-2 site selelction 3-1 Web-based 1-2 SNMP agent 1-2 mounting the switch specifications in a rack 3-3...
  • Page 62 ES3628EA E112007-DT-R01 150200064200A...

Table of Contents