Step 4. Positioning, Leveling, and Securing
the Fireplace
The diagram below shows how to properly position, level,
and secure the fireplace.
NAILING
TABS
(BOTH SIDES)
Figure 31. Proper Positioning, Leveling, and
Securing of a Fireplace
• Place the fireplace into position.
• Level the fireplace from side to side and from front to
back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by nailing or screwing.
• Holes are provided in the base pan for securing the unit
to the floor.

Step 5. The Gas Control System

WARNING: THIS UNIT IS NOT FOR USE WITH
!
SOLID FUEL.
IPI PILOT
Figure 32. Gas Control System
Intermittent Pilot Ignition (IPI) System
This system includes a 3V control valve, electronic module
and intermittent pilot.
WARNING: CONTINUOUS 110-120 VAC
!
SERVICE MUST BE WIRED DIRECTLY TO
THE FIREPLACE JUNCTION BOX IN A IPI SYSTEM.
33
FLAME
SENSOR
ROD