Wiring; 3-3.1 Immersion Heater; Oso Dualstream - OSO Dualstream Technical Installation Manual

Capacity 120 - 380 litres
Table of Contents

Advertisement

3-3 WIRING

3-3.1 Immersion Heater and Thermostat
The immersion heater must be permanently connected
to the electrical supply through a double-pole linked
switch with a minimum break capacity of 13 amps.
Please use the cable glands supplied to protect and fix
electrical cables at cable entry points.
Immersion Heater 240 V - 1 phase
WARNING: Isolate from main electricity supply before
any adjustments are made.
IMPORTANT!
1.
WATER IN BEFORE POWER ON.
2.
All internal wiring is factory mounted. Please do
not touch.
3.
Regulations require competent person.
4.
Check wiring is in accordance with diagram.
5.
The safety cut-out operates if:
- Wiring is incorrect
- The immersion heater is defective
- Thermostat is set too high or is defective.
Reduce thermostat setting and press the reset button.
If still out of operation, contact competent person.
Immersion heater, part no. 71255.
Thermostat, part no. 80020.
TECHNICAL INFORMATION 3
IMMERSION HEATER THERMOSTAT
9
(LEFT HAND THERMOSTAT)
WIRING DIAGRAM
Fig. 3-3a