Download Print this page
Fantom FM760 Instruction Manual
Hide thumbs Also See for FM760:

Advertisement

iNSTRUCTION
MANUAL
VACUUM CLEANER
F 7
Contents
IMPORTANT
SAFETY
INSTRUCTIONS
.......... 1
NAME
OF EACH
PART ..........................................
3
PREPARATION
BEFORE
USE ............................. 4
USING
THE VACUUM
CLEANER
..................... 6
USING
THE ATTACHMENTS
............................ 8
EMPTYING
THE DUST
COMPARTMENT
....... 9
CLEANING
THE
FILTERS
..................................
10
CLEARING
BLOCKAGES
IN THE
SUCTION
HOSE
AND
CLEANING
THE
........ 11
AG ITATO R ASSEMBLY
REPLACEMENT
INSTRUCTIONS
................... 12
TROUBLESHOOTING
........................................
16
REPLACEMENT
PARTS
.....................................
.16
LIMITED
WARRANTY
.........................................
17
I HOUSEHOLD
USE ONLY
I

Advertisement

loading

Summary of Contents for Fantom FM760

  • Page 1 iNSTRUCTION MANUAL VACUUM CLEANER Contents IMPORTANT SAFETY INSTRUCTIONS ..1 NAME OF EACH PART .......... PREPARATION BEFORE USE ......4 USING THE VACUUM CLEANER ..... 6 USING THE ATTACHMENTS ......8 EMPTYING THE DUST COMPARTMENT ..9 CLEANING FILTERS ........CLEARING BLOCKAGES IN THE...
  • Page 2 When using an electrical appliance, basic precautions should always followed, including the following. READ ALL INSTRUCTIONS BEFORE USING THISVACUUM CLEANER WA R N IN G - To reduce the risk of fire, electric shock or injury: 1. Do not leavethe vacuum cleaner when plugged...
  • Page 3 16. Do not touch the agitatorwhile it is spinning. 17. Do not place any heavy items on top of the vacuum cleaner. 18. Do not step on the hose or pull it too strongly. 19. Do not pick up items such aspiecesofwastepaperorclothwhichlookas though they may cause the hose to become blocked.
  • Page 4 (FRONT) (REAR 1 Handle Release Button C Hose Button A Cord Storage Hooks Button B Switch Carrying Handle ..Crevice Tool Release ' Tool Dust --Filter Cover Compartment Power Cord Plug Height Adjustment Rug/Floor (Tools) SELECTOR Headlight Lever Lever •_ Set the ON/OFF switch to"...
  • Page 5 Caution: Do not connect the power cord plug to the wall outlet until assembly is completed. Attaching the handle Set the vacuum cleaner Insert the handle as shown in the illustration. to the upright position.
  • Page 6 WINDING THE POWER CORD Wind the power cord around the cord Hook the power cord over the clip which is located on storage hooks. the upper cord storage as shown. Secure the power cord plug on the power cord. Cord StoraG Hooks RELEASING THE POWER CORD...
  • Page 7 ON/OFF SWITCH ® Start or stop vacuum cleaner by pushing on the switch. ADJUSTING THE HANDLE The handle ofthis vacuum cleanercan be setto one of three positions -Upright, Normal or Parallel. Place your foot on handle release lever as shown and pull backon the handle until it releasesfrom its upright position.
  • Page 8 HEIGHT ADJUSTMENT LEVER autio n: Before using the height adj- ustment lever, please make sure the nozzle head is tilted Height Adjustment Lever-_ backward from the floor. • The nozzle head can be (__._ ozzle Head adjusted to four different -_-'-- _ ._.._ height settings.
  • Page 9 Caution: When using one of theattachmentsduringcleaning,setthevacuum cleaner to the upright position. Remove the attachments from vacuum cleaner. Wand Press the release button C to Release disconnect the handle from the Crevice Tool Button C vacuum cleaner. Caution: When removing the attachments,pull ®...
  • Page 10 Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnectthe power cord from the wall outlet before cleaning. Empty the dustcompartmentwhen Press the release button A meanwhile contents reach the MAX mark. press the release button B to remove the dust compartment.
  • Page 11 Remove the dust compartment.(refer to page g) Set the dust compartment to the parallel position.Open the trapdoor,then push the release button E and pull out the main filter. OThe main filter and prefilter will be removed at the same time. Caution: Do not push the release button...
  • Page 12 Caution: Be sureto turn the ON/OFF switch tothe "OFF" p.osition and disconnect power cord from the wall out!e! before clearing any blockages in the suct on nose an(] c eaning the agkator assembly. Clearing blockages in the suction hose ' 1 Set the v acu u7 c,eaner to the u p ight position.
  • Page 13 Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect power cord from the wall outlet before replacing any of the parts below. REPLACING THE HEADLIGHT LAMP Set the vacuum cleanertotheparallel position. Loosen the screws to remove the lens.
  • Page 14 Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect power cord from the wall outlet before replacing any of the parts below. REPLACING THE FLAT BELT Remove the bottom plate. (refer to page 14) Lift out the agitator assembly,and then remove...
  • Page 15 REMOVING THE BOTTOM PLATE Pull here Set thevacuum cleanerto parallel position and turn it over. Latch Slide the latch in the direction of the arrow. Remove the bottom plate by pulling the tabs as illustrated. Plate REATTACHING THE BOTTOM PLATE Insert the projection on the bottom plate...
  • Page 16 REPLACING THE HEPA FILTER Under normal usage, the HEPAFilter will not require replacement; however, vacuuming large amounts ofextremely fine dust, powder or similar material over a long period of time may decrease airflow performance through the filter. Ifthis occurs, it may become necessary to replacethe HEPA...
  • Page 17 If there is a problem with the vacuum cleaner, carry out the following checks to find the cause. If the problem still persists after the checks have been made, do not use the vacuum cleaner to prevent the possibility of an accident occurring.
  • Page 18 RETURN TO FANTOM, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901 Model FM760 Appliance model Date purchased Name of store Owner's name Address City...