Kenmore 795.7032 series Use & Care Manual page 34

Bottom freezer refrigerator
Table of Contents

Advertisement

Available languages

Available languages

iNSTALLATiON
iNSTRUCTiONS
Instatl the shutoff valve on the nearest frequently
used
drinking
water line.
1. SHUT OFF THE MAIN
WATER SUPPLY
Turn on the nearest faucet to relieve the pressure on
the line.
2. CHOOSE THE VALVE LOCATION
Choose a location for the valve
that is easily accessible,
it is best to
connect into the side of a vertical
water pipe. When it is necessary to
connect into a horizontal
water pipe,
make the connection
to the top or
side, rather than at the bottom, to
avoid drawing
off any sediment from the water pipe.
3. DRILL THE HOLE FOR THE VALVE
Drill a I/4 in. hole in the water pipe using a sharp bit.
Remove any burrs resulting from
drilling
the hole in the pipe. Be
careful not to allow water to
drain into the drill. Failure to
drill a 1/4 in. hole may result
in reduced
ice production
or
smaller cubes.
NOTE: The hookup line cannot be white, plastic
tubing. Licensed plumbers
must use only copper
tubing NDA tubing :#49595 or 49599 or Cross Link
Polyethylene
(PEX) tubing.
4. FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe with
the pipe clamp.
Pipe Clamp-
Saddle-Ty_
Shutoff Valve
Vertical
Cold
Water
Pipe
NOTE: Commonwealth
of Massachusetts
Plumbing
Codes 248CMR shall be adhered to. Saddle valves are
illegat and use is not permitted
in Massachusetts.
Consult with your licensed plumber.
5. TIGHTEN
THE PIPE CLAMP
Tighten
the clamp
screws
until the sealing
washer
begins
to swell.
NOTE: Do not overtighten clamp or you may crush the
tubing.
Washer
Pipe Clamp
Clamp Screw_
,--------inlet End
o
7.
ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled
in the walt
or floor (behind the refrigerator
or adjacent
base
cabinet)
as close to the walt as possible.
NOTE: Be sure there is sufficient extra tubing (about
8 feet coiled into 3 turns of about 10 in. diameter) to
allow the refrigerator
to move out from the wan after
instaWation.
CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect
it to the shutoff valve. Make sure the tubing is futty
inserted into the valve. Tighten the compression nut
securely.
Saddle-Type
Shutoff Valve _
X
,
Packing Nu_
Outlet Valve--
b
ression Nut
Ferrule (sleeve)
NOTE: Commonwealth
of Massachusetts Plumbing
Codes 248CMR shaw be adhered to. Saddle valves are
illegal and their use is not permitted
in
Massachusetts. Consult with your licensed plumber.
34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents