Digital blood pressure monitor
Hide thumbs Also See for UA-774:

Advertisement

Digital Blood Pressure Monitor
Model UA-774
Instruction Manual
Manuel d'instructions
Manual de Instrucciones
Manuale di Istruzioni
1WMPD4000734C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UA-774 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for A&D UA-774

  • Page 1 Digital Blood Pressure Monitor Model UA-774 Instruction Manual Manuel d’instructions Manual de Instrucciones Manuale di Istruzioni 1WMPD4000734C...
  • Page 2: Table Of Contents

    ENGLISH Contents Dear Customers..............2 Preliminary Remarks ............. 2 Precautions................2 Parts Identification..............3 Symbols................4 Using The Monitor ..............5 Installing / Changing The Batteries ........5 Connecting The Air Hose ..........5 Selecting The Correct Cuff ..........5 Attaching The Arm Cuff ...........
  • Page 3: Dear Customers

    Dear Customers Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time.
  • Page 4: Parts Identification

    Parts Identification DC jack START 2 button Display Green illumination START 1 button Orange illumination 1.5V Batteries R6P, LR6, AA Air connector plug Air socket Arm cuff Air hose Proper fit range Index mark Battery cover Battery compartment The START Button Operations Normal measurement with storing data Press the button.
  • Page 5: Symbols

    Symbols Symbols Function / Meaning Recommended Action Standby and Turn the device on. Battery installation guide Direct current Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while Measurement is in measurement is in progress.
  • Page 6: Using The Monitor

    32 cm to 42 cm Large cuff UA-CUFBLALB 22 cm to 32 cm Medium cuff UA-CUFCAULB, UA-CUFDAULB Small cuff - - Arm size: The circumference at the biceps. Note: This UA-774 monitor is NOT designed for using a small cuff. English 5...
  • Page 7: Attaching The Arm Cuff

    Using The Monitor Rolled up shirtsleeve Attaching The Arm Cuff 1. Wrap the cuff around the upper arm, about 2 - 3 cm above the elbow, as shown. Cuff Place the cuff directly against the skin, Air Hose as clothing may cause a faint pulse and result in a measurement error.
  • Page 8: Measurements

    Measurements Model UA-774 is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expected to exceed 230 mmHg, read "Measurement with the desired systolic pressure" on the next page.
  • Page 9: Measurement With The Desired Systolic Pressure

    Should the device detect a condition that is abnormal, it will stop the measurement and display an error symbol. Refer to page 4. Model UA-774 is intended for use by adults only. Consult with your physician before using this device on a child. A child should not use this device unattended.
  • Page 10: Operation Mode

    Operation Mode 1. Normal measurement with storing data ( Refer to page 7) Press the button. Blood pressure is measured and START 1 START 2 data is stored within the device. The device can store the last thirty sets of data for each button.
  • Page 11: What Is An Irregular Heartbeat

    What Is An Irregular Heartbeat? Model UA-774 blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement.
  • Page 12: Blood Pressure Variations

    Blood Pressure Variations An individual’s blood pressure varies greatly on a daily and seasonal basis. It may vary by 30 to 50 mmHg due to various conditions during the day. In hypertensive individual variations are even more pronounced. Normally, the blood pressure rises while at work or play and falls to its lowest levels during sleep.
  • Page 13: Maintenance

    2 years, to ensure proper functioning and accuracy. Please contact either your authorized dealer or A&D for maintenance. Technical Data Type UA-774 Measurement method Oscillometric measurement Measurement range Pressure: 20 - 280 mmHg...