Remedy For The Interference Toa Vhf Radiotelephone - Furuno GR-80 Operator's Manual

Dgps beacon receiver
Table of Contents

Advertisement

REMEDY FOR THE INTERFERENCE TO
A VHF RADIOTELEPHONE
If a VHF radiotelephone is interfered by signal from the data cable between GPS receiver
and the GR-80, follow the procedure shown below.
Procedure
1. The screen of the data cable is grounded effectively.
GR-80 DATA Connector
GR-80 DATA Connector
DATA Cable
Shield
Signal Cable
DATA Cable
Solder the shield
to pin No.7.
Two Cables
23
The shield must be grounded
through the cable clamp
The shield must be grounded
through the cable clamp.
Wind copper tape or mesh tape around
the cable before clamping.

Advertisement