Specifications - Navman G-PILOT 3380 Operation Manual

Hide thumbs Also See for G-PILOT 3380:
Table of Contents

Advertisement

10 Specifications

Electrical
Supply voltage: 10.5 to 30.5 V DC.
Supply current ( at 13.8 V):
Without backlighting: 160 mA.
With full backlighting: up to 410 mA.
Other optional instruments: refer to the
instrument's operation manual.
Interfaces
NavBus: connection to MCU and other Navman
instruments.
AP3380 Display unit power/data cable wires:
Pin
Wire color
5
Red
1
Black
6
Orange
4
Blue
7
Yellow
3
White
8
Green
2
Brown
Pin
Wire color
5
Red
1
Black
6
Orange
4
Blue
7
Yellow
3
White
8
Green
2
Brown
G-PILOT 3380 and Operation Manual
Black connector - Power
Signal
Power positive, 10.5 to 30.5 V DC
Power negative
NavBus +
NavBus -
Factory use (isolate, do not cut)
Factory use (isolate, do not cut)
External alarm, switched to ground, 30 V DC and 250 mA max.
+9V out
Green connector - NavBus expansion
Signal
Factory use (isolate, do not cut)
Power negative
NavBus +
NavBus -
Factory use (isolate, do not cut)
Factory use (isolate, do not cut)
Factory use (isolate, do not cut)
+9V out
Standards compliance
EMC compliance:
USA (FCC): Part 15 Class B
Europe (CE): IEC 60945:2002 Clause 9 & 10.
New Zealand and Australia (C Tick):
IEC 60945:2002 Clause 9.
Environment:
IPx6 and IPx7 - completely waterproof.