Heat pump thermostat
Table of Contents

Advertisement

Existing
Function
Terminals
or
Common
C
X
Power
R
Compressor
Y
1st Stage
Heat
Aux. Heat
W2
Fan
G
C/O Valve
B
Heat
C/O Valve
O
Cool
System Monitor/
L
System Defrost
or
Em. Heat
K
E
Multiple Aux.
W3
Heat Loads
LED Indication
2nd Stage
Compressor
2nd Stage
Cool
Configure O/B (select models) in Installer Setup.
When W2 is not used, configure W2 cycle rate to NC.
Terminal is for multiple auxiliary heat loads such as contactors, sequencers,
or relays.
Terminal must be connected to the transformer common.
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER (CUSTOMER PART NUMBER)
Electromechanical
X
X
X
R
R
R
Y
Y
Y1
W1
W1
W2
W2
W2
G
G
G
B
B
B
O
O
O
L
E
E
E
W3
W3
W3
X2
X1
X2
T841A1365 (121000012)
Electronic Replacement or Upgrade
®
Chronotherm
III
C
C
R
R
or
Y1
Y
Y
W1
W1
W2
W2
G
G
B
B
O
O
L
L
E
E
X1
X2
If multiple auxiliary heat loads are used, connect to W2 (Aux W8900B)
terminal.
Do not remove factory-installed jumper.
L terminal is powered continuously when thermostat is in Em. Ht. position.
LED is energized when terminal is powered.
T841A1357
SQUARE D/SUN DIAL
Chronotherm
IV
C
C
C
R
R
R
Y1
Y
Y1
W1
W1
W1
W2
W2
W2
G
G
G
or
or
B
O/B
B
B
or
or
O
O/B
O
O
L
L
L
E
E
E
X1
C
R
Y1/W1
Aux.
G
O/B
O/B
O/B
O/B
L
E
X2
W2
Y2
M13201