Existing
Function
Terminals
Common
B
Power
R
Compressor
Y
1st Stage
–
Heat
Aux. Heat
W
Fan
G
Outdoor
T
Thermistor
Outdoor
X2
Thermostat
Cooling
O
Changeover
System
F
Monitor
2nd Stage
–
Compressor
2nd Stage
–
Cool
For best performance, use a NEMA standard transformer.
Terminal B (C) must be connected to transformer common.
Configure O/B (select models) in Installer Setup.
Leave factory-installed jumper in place.
T874R1566/Q674L1538
Electromechanical
B
B
B
R
R
R
Y
Y
Y
–
–
–
W
W
W
G
G
G
T
T
T
X2
X2
X2
O
O
O
F
F
F
–
–
–
–
–
–
TYPICAL THERMOSTATS AND SUBBASES — HONEYWELL MODEL NUMBER
Electronic Replacement or Upgrade
®
Chronotherm
III
C
C
R
R
or
Y1
Y
Y
W1
W1
W2
W2
G
G
E
E
O
O
L
L
–
–
–
–
No connection. Tape off.
When W2 is not used, configure W2 cycle rate to NC.
LED is energized when terminal is powered.
L terminal is powered continuously when thermostat is in Em. Ht. position.
T841A1068
HONEYWELL
MODELS USING OUTDOOR RESET
Chronotherm
IV
C
C
C
R
R
R
Y1
Y
Y1
W1
W1
W1
W2
W2
W2
G
G
G
E
E
E
or
or
O
O/B
O
O
L
L
L
–
–
–
–
–
–
T874R1053/Q674L1140
C
R
Y1/W1
–
Aux.
G
E
O/B
O/B
L
W2
Y2
M13189
70-6627 • 65