1 Specifications

1.1
CVW-EXA284 (H: 84 7/8", L: 96 3/8") / CVW-EXA224 (H: 84 7/8", L: 144 5/8")
Model Name
General
Application:
Cooling Capacity:
Discharge Air:
Evaporator Temperature:
Defrost (Off-cycle)
Frequency: (times per day)
Termination Temperature:
Failsafe/Duration:
Electrical
Anti-condensation Heater:
Fan
Standard:
High Efficiency:
Motor
Exterior:
Lights
Interior:
Total:
Components
Anti-condensation Heater
Fan
Standard:
High Efficiency:
Motor
Fan Blade Pitch:
Illumination:
Pipe Diameter:
Measurements
Outer Dimensions:
Open Space:
Display Area:
Effective Capacity:
Weight:
Waste Outlet Dimensions:
Standard Ambient Conditions: Indoor temperature 75°F (24°C), relative humidity 55%, wind speed under 39.4 fpm.
All specifications are based upon temperature, humidity, and wind speed values equal to or less than Standard Ambient Conditions.
SANYO Cases described in this manual are designed for indoor use only. SANYO Cases should not be exposed to direct sunlight.
Fan Motors are available in Standard-type (AC Fan Motors) or High Efficiency-type (DC Fan Motors).
Display Area Effective Capacity data specification based on 4 (four) 20" shelves set at 0° (flat). Any variations from this specification will
affect overall data.
CVW-EXA284
Medium Temperature (Fresh Produce)
1224 BTU/h/ft. (2,880W)
34°F (1.11°C)
28°F (-2.22°C)
Medium Temperature
6, once every 4 hours
50.0°F
30 minutes
1-phase 120V
N/A
195W
84W
2 Rows of Lamps
110W
Top Panel
N/A
Handrail
N/A
Standard
110W
N/A
SPFBE141 x 3
SSC2B12CNHBV1 x 3
Inside:#128×2, Outside:#128 x 1
FO32/XP (T8) (Output 32W)
Liquid 3/8", Suction 3/4"
84 7/8" (H) × 42 1/2" (W) × 96 3/8" (L)
61 1/2"
73.4 sq.ft.
72.0 cu.ft.
620.5 lbs
1 1/2"
Medium Temperature (Fresh Produce)
1224 BTU/h/ft. (4,321W)
N/A
2.28A
1.29A
0.94A
2 Rows of Lamps
N/A
Top Panel
N/A
Handrail
0.94A
Standard
SPFBE141 x 3 , SPFBE91T x 2
SSC2B12CNHBV1 x 3 , SSC2B12BVHBV1 x 2
Inside:#128 x 3, Outside:#117 x 2
FO32/XP (T8) (Output 32W)
84 7/8" (H) × 42 1/2" (W) × 144 5/8" (L)
5
CVW-EXA224
34°F (1.11°C)
28°F (-2.22°C)
Medium Temperature
6, once every 4 hours
50.0°F
30 minutes
1-phase 120V
N/A
N/A
285W
3.42A
126W
1.93A
166W
1.42A
N/A
N/A
N/A
N/A
166W
1.42A
N/A
Liquid 3/8", Suction 3/4"
61 1/2"
110.1 sq.ft
108.0 cu.ft.
892.0 lbs
1 1/2"

Hide quick links: