Replacing Electronic Ballasts - Sanyo CVW-EXA284 Installation & Service Manual

Multi-deck fresh produce cases
Table of Contents

Advertisement

7.2

Replacing Electronic Ballasts

Exterior Top
Panel
To replace electronic ballasts:
① Remove the Exterior Top Panel.
② Unplug the Electronic Ballast Harness(es).
③ Remove the Electronic Ballast(s).
Electronic Ballast Part Codes
Type
3-lamp
QHE3X32T8/UNV ISN-SC-1-CC-B
2-lamp
QHE2X32T8/UNV ISN-SC-1-CC-B
WARNING!
Make sure that all Electronic Ballasts Harness plugs are placed firmly in their sockets to prevent damage to the ballast
and/or the case.
Model
8FC05400000301
8FC05400000201
Ballast
CVW-EXA124/224
Part Number
Quantity used
26
CVW-EXA184/284
Quantity used
2
-
-
2