Reading Commands; Storing Commands - AND CC-Link Interface AD-4402-OP-20 Instruction Manual

Cc-link interface
Table of Contents

Advertisement

Setpoints (RWw0000 to RWw000B)
Request flag to store setpoint (RY0000)
Reply flag to store setpoints (RX0000)
4.3.5.
4.3.5.
4.3.5.
4.3.5.

Reading Commands

Reading Commands
Reading Commands
Reading Commands
1 Set a material code (No. 33) or recipe code (No. 57) in the storing command (RWw000E).
2 Turn on the Read/Write selection (RY0003).
3 Set the kind of data to the command code (RWw000E)
4 The result is output to the reply register (RWr000C to 000D).
Read/Write selection (RY0003)
Command request flag (RY0002)
Command code reply (RWr000E)
Command data reply (RWr000C, RWr000D)
Command reply flag (RX0002)
4.3.6.
4.3.6.
4.3.6.
4.3.6.

Storing Commands

Storing Commands
Storing Commands
Storing Commands
1 Set a material code (No. 33) or recipe code (No. 57) in the storing command (RWw000E).
2 Turn off the Read/Write selection (RY0003).
3 Set the kind of data to the command code (RWw000E)
4 Set data to the command register (RWw000C, RWw000D).
Read/Write selection (RY0003)
Command data (RWw000C, RWw000D)
Command request flag (RY0002)
Command code reply (RWr000E)
AD-4402-20
Command code (RWw000E)
Read/Write reply (RX0003)
Command code (RWw000E)
Read/Write reply (RX0003)
Command reply flag (RX0002)
Page 17
Step 3
Step 4
Step 2
Step 2

Advertisement

Table of Contents
loading

Table of Contents