External Inspection & Cleaning Of The Base-Ring Filter - Kenmore 153.336930 Use & Care Manual

30/40 gallon tall
Hide thumbs Also See for 153.336930:
Table of Contents

Advertisement

CONNECTORS
IGNITER
WIRE
MANIFOLD COMPONENT
BLOCK "-__
PILOT TUBE
MANIFOLD DOOR
FIGURE 31.
PILOT / THERMOPILE
J
ASSEMBLY
SCREW
,,'
BURNER
AND
OTHER
FITTINGS NOT SHOW
FOR CLARITY.
THERMAL SWITCH (2)
MANIFOLD
COMPONENT
BLOCK
@
RED(+)THERMALSWITCH
WIRE
CONNECTS TO THE GAS CONTROL
VALVE\THERMOSTAT.
(-) THERMOPILE WIRE
CONNECTS TO THE GAS CONTROL
VALVE\THERMOSTAT.
RED THERMAL SWITCH WIRE
CONNECTIONS AT MANIFOLD DOOR
6,
Read this step carefully before proceeding.
Using the old
pilot/pilot tube assembly as a guide, bend the new pilot tube
to match the old one. Make only the bends closest to the
pilot before going to the next step.
PILOT/THERMOPILE
ASSEMBLY
PI LOT........_
THERMOPILE
IGNITER
CONNECTOR
ASSEMBLY
CONNECTORS
(RED WIRES)
FOR CLARITY,
PILOT
TUBE
NOT SHOWN
.
FIGURE 32.
7.
Route the new pilot tube and wires through the opening in the
manifold door. See Figure 31.
8.
Using the pilot screw removed earlier, attach the new pilot/
thermopite assembly.
Reattach the burner to the manifold
using the screws removed earlier. NOTE: Make sure the
burner scoop is oriented to the pilot side of the manifold tube
(Figure 30).
9.
Reinstall the manifold component block in the manifold door.
Ensure that the pilot tube and wires are positioned as shown
in Figure 33.
10. Carefully bend the new pilot tube to match the bend of the
manifold tube. NOTE: When bending, DO NOT crimp or
crease the pilot tube.
11. Before you proceed to the next step, install the new brass
ferrule nut in the gas control valve/thermostat's
pilot tube
opening, HAND TIGHT ONLY.
12. Install the manifold/burner assembly. Refer to the "Replacing
the Manifold/Burner Assembly" section for instructions.
IGNITER WIRE PASSES
THROUGH CENTER OF
MANIFOLD COMPONENT
BLOCK (SMALLEST HOLE)
THERMOPILE WIRES PASS
THROUGH TOP HOLE OF
MANIFOLD COMPONENT
BLOCK
PILOT TUBE PASSES
THROUGH BOTTOM HOLE
OF MANIFOLD COMPONENT
BLOCK (LARGEST HOLE)
FIGURE 33.
External
Inspection
& Cleaning
of the
Base-Ring
Filter
1,
At least annually, check the base-ring filter (Figure 34) for
any dust or debris that may have accumulated
on the filter
screen. NOTE: If the water heater is located in an area that
is subjected to tint and dirt, it may be necessary
to check
the base-ring filter more frequently.
2.
Follow the Lighting Instructions to turn off the water heater
and allow it to coot for 10 minutes before attempting to clean
the base-ring filter.
3.
Use a vacuum cleaner with a hose attachment
to remove
any dust or debris that may have accumulated
on the filter.
NOTE: If unable to inspect or clean the base-ring filter, follow
the "Cleaning the Combustion Chamber and Flame-arrestor"
instructions.
4,
After the base-ring
filter has been cleaned,
follow the
Lighting Instructions to return the water heater to service.